Early out-of-hospital experience with an impedance-compensating low-energy biphasic waveform automatic external defibrillator. 1997

R D White
Department of Anesthesiology, Mayo Clinic, Rochester, MN 55905, USA.

Impedance-compensating low-energy biphasic truncated exponential (BTE) waveforms are effective in transthoracic defibrillation of short-duration ventricular fibrillation (VF). However, the BTE waveform has not been examined in out-of-hospital cardiac arrest (OHCA) with patients in prolonged VF often associated with myocardial ischemia. The objective of this study was to evaluate the BTE waveform automatic external defibrillator (AED) in the out-of-hospital setting with long-duration VF. AEDs incorporating a 150-J BTE waveform were placed in 12 police squad cars and 4 paramedic-staffed advanced life support ambulances. AEDs were applied to arrested patients by first-arriving personnel, whether police or paramedics. Data were obtained from PC Data Cards within the AED. Defibrillation was defined as at least transient termination of VF. Ten patients, 64 +/- 14 years, were treated for VF with BTE shocks. Another 8 patients were in nonshockable rhythms and the AEDs, appropriately, did not advise a shock. Five of the 10 VF arrests were witnessed with a 911 call-to-shock time of 6.6 +/- 1.7 minutes. VF detection and defibrillation occurred in all 10 patients. Spontaneous circulation was restored in 3 of 5 witnessed arrest patients and 1 survived to discharge home. Fifty-one VF episodes were converted with 62 shocks. Presenting VF amplitude and rate were 0.43 +/- 0.22 (0.13-0.86) mV and 232 +/- 62 (122-353) beats/min, respectively, and defibrillation was achieved with the first shock in 7 of 10 patients. Including transient conversions, defibrillation occurred in 42 of 51 VF episodes (82%) with one BTE shock. Shock impedance was 85 +/- 10 (39-138) ohms. Delivered energy and peak voltage were 152 +/- 2 J and 1754 +/- 4 V, respectively. The average number of shocks per VF episode was 1.2 +/- 0.5 (1-3). More than one shock was needed in only 9 episodes; none required > 3 shocks to defibrillate. Impedance-compensating low-energy BTE waveforms terminated VF in OHCA patients with a conversion rate exceeding that of higher energy monophasic waveforms. VF was terminated in all patients, including those with high impedance.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D004554 Electric Countershock An electrical current applied to the HEART to terminate a CARDIAC ARRHYTHMIA. Cardiac Electroversion,Cardioversion,Defibrillation, Electric,Electroversion, Cardiac,Electrical Cardioversion,Electroversion Therapy,Therapy, Electroversion,Cardiac Electroversions,Cardioversion, Electrical,Cardioversions,Cardioversions, Electrical,Countershock, Electric,Countershocks, Electric,Defibrillations, Electric,Electric Countershocks,Electric Defibrillation,Electric Defibrillations,Electrical Cardioversions,Electroversion Therapies,Electroversions, Cardiac,Therapies, Electroversion
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D004632 Emergency Medical Services Services specifically designed, staffed, and equipped for the emergency care of patients. Emergency Care,Emergency Health Services,Emergicenters,Prehospital Emergency Care,Emergency Care, Prehospital,Emergency Services, Medical,Medical Services, Emergency,Services, Emergency Medical,Emergency Health Service,Emergency Medical Service,Emergency Service, Medical,Emergicenter,Health Service, Emergency,Health Services, Emergency,Medical Emergency Service,Medical Emergency Services,Medical Service, Emergency,Service, Emergency Health,Service, Emergency Medical,Service, Medical Emergency,Services, Emergency Health,Services, Medical Emergency
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly

Related Publications

R D White
October 1987, Acta anaesthesiologica Scandinavica,
R D White
March 1989, The New England journal of medicine,
R D White
November 1999, Pacing and clinical electrophysiology : PACE,
R D White
January 2006, Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation,
R D White
July 1983, The American journal of physiology,
Copied contents to your clipboard!