Ventricular fibrillation detection using the evoked electrogram from the braided endocardial defibrillation lead. 1992

R M Lu, and A K Dawson
Telectronics Pacing Systems, Englewood, Colorado 80112.

Life-threatening consequences can be the result of inappropriate classification of ventricular fibrillation for patients with implantable cardioverter defibrillators. The objective of this study was to determine if analysis of the asynchronously paced evoked electrogram using the braided endocardial defibrillation lead could improve the detection of ventricular fibrillation. The depolarization portion of the evoked electrogram was integrated to obtain the paced depolarization integral. The results demonstrated that the mean of the paced depolarization integral, its SD, and the mean +/- SD were significantly different between sinus rhythm and ventricular fibrillation (p < 0.005, p < 0.05, p < 0.01, respectively). These results suggest that the paced depolarization integral obtained with the braided endocardial defibrillation lead could improve the specificity and sensitivity of ventricular fibrillation detection.

UI MeSH Term Description Entries
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D013552 Swine Any of various animals that constitute the family Suidae and comprise stout-bodied, short-legged omnivorous mammals with thick skin, usually covered with coarse bristles, a rather long mobile snout, and small tail. Included are the genera Babyrousa, Phacochoerus (wart hogs), and Sus, the latter containing the domestic pig (see SUS SCROFA). Phacochoerus,Pigs,Suidae,Warthogs,Wart Hogs,Hog, Wart,Hogs, Wart,Wart Hog
D014693 Ventricular Fibrillation A potentially lethal cardiac arrhythmia that is characterized by uncoordinated extremely rapid firing of electrical impulses (400-600/min) in HEART VENTRICLES. Such asynchronous ventricular quivering or fibrillation prevents any effective cardiac output and results in unconsciousness (SYNCOPE). It is one of the major electrocardiographic patterns seen with CARDIAC ARREST. Fibrillation, Ventricular,Fibrillations, Ventricular,Ventricular Fibrillations
D017147 Defibrillators, Implantable Implantable devices which continuously monitor the electrical activity of the heart and automatically detect and terminate ventricular tachycardia (TACHYCARDIA, VENTRICULAR) and VENTRICULAR FIBRILLATION. They consist of an impulse generator, batteries, and electrodes. Cardioverter-Defibrillators, Implantable,Implantable Cardioverter Defibrillator,Implantable Cardioverter-Defibrillators,Implantable Defibrillators,Cardioverter Defibrillator, Implantable,Cardioverter Defibrillators, Implantable,Cardioverter-Defibrillator, Implantable,Defibrillator, Implantable,Defibrillator, Implantable Cardioverter,Defibrillators, Implantable Cardioverter,Implantable Cardioverter Defibrillators,Implantable Cardioverter-Defibrillator,Implantable Defibrillator

Related Publications

R M Lu, and A K Dawson
April 1993, The American journal of cardiology,
R M Lu, and A K Dawson
February 1977, The Journal of thoracic and cardiovascular surgery,
R M Lu, and A K Dawson
December 2017, Circulation. Arrhythmia and electrophysiology,
R M Lu, and A K Dawson
June 2013, Journal of cardiovascular electrophysiology,
R M Lu, and A K Dawson
September 2021, JACC. Clinical electrophysiology,
R M Lu, and A K Dawson
January 1983, Australasian physical & engineering sciences in medicine,
R M Lu, and A K Dawson
October 2007, Archives of disease in childhood,
R M Lu, and A K Dawson
March 1993, Pacing and clinical electrophysiology : PACE,
Copied contents to your clipboard!