[Unexpected malposition of a ventricular pacemaker electrode]. 1992

M Jereczek, and B Levenson
Abteilung Kardiologie und Pulmologie, Klinikum Steglitz der Freien, Universität Berlin.

Ten years after mitral-valve replacement, a 69-year-old patient underwent VVI pacemaker implantation because of symptomatic bradyarrhythmia. Postoperatively, the electrocardiogram showed a right bundle branch pattern under ventricular stimulation while the threshold was optimal. Under fluoroscopy, we suspected a malposition of the electrode outside the right ventricle in the LAO and lateral view. This could not be verified by echocardiography, whereas contrast angiography of the right ventricle proved the extracavitary position of the electrode under the inferior wall of the left ventricle, probably in the middle cardiac vein. The electrode position was operatively corrected without complications. We discuss different ways of malposition and their detection by considering electrocardiographic configuration and fluoroscopy in LAO and lateral view.

UI MeSH Term Description Entries
D008943 Mitral Valve The valve between the left atrium and left ventricle of the heart. Bicuspid Valve,Bicuspid Valves,Mitral Valves,Valve, Bicuspid,Valve, Mitral,Valves, Bicuspid,Valves, Mitral
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D011183 Postoperative Complications Pathologic processes that affect patients after a surgical procedure. They may or may not be related to the disease for which the surgery was done, and they may or may not be direct results of the surgery. Complication, Postoperative,Complications, Postoperative,Postoperative Complication
D012086 Reoperation A repeat operation for the same condition in the same patient due to disease progression or recurrence, or as followup to failed previous surgery. Revision, Joint,Revision, Surgical,Surgery, Repeat,Surgical Revision,Repeat Surgery,Revision Surgery,Joint Revision,Revision Surgeries,Surgery, Revision
D003952 Diagnostic Imaging Any visual display of structural or functional patterns of organs or tissues for diagnostic evaluation. It includes measuring physiologic and metabolic responses to physical and chemical stimuli, as well as ultramicroscopy. Imaging, Diagnostic,Imaging, Medical,Medical Imaging
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D004567 Electrodes, Implanted Surgically placed electric conductors through which ELECTRIC STIMULATION is delivered to or electrical activity is recorded from a specific point inside the body. Implantable Electrodes,Implantable Stimulation Electrodes,Implanted Electrodes,Implanted Stimulation Electrodes,Electrode, Implantable,Electrode, Implantable Stimulation,Electrode, Implanted,Electrode, Implanted Stimulation,Electrodes, Implantable,Electrodes, Implantable Stimulation,Electrodes, Implanted Stimulation,Implantable Electrode,Implantable Stimulation Electrode,Implanted Electrode,Implanted Stimulation Electrode,Stimulation Electrode, Implantable,Stimulation Electrode, Implanted,Stimulation Electrodes, Implantable,Stimulation Electrodes, Implanted
D005260 Female Females
D005548 Foreign-Body Migration Migration of a foreign body from its original location to some other location in the body. Foreign Body Migration,Foreign-Body Migrations,Migration, Foreign-Body,Migrations, Foreign-Body
D006350 Heart Valve Prosthesis A device that substitutes for a heart valve. It may be composed of biological material (BIOPROSTHESIS) and/or synthetic material. Prosthesis, Heart Valve,Cardiac Valve Prosthesis,Cardiac Valve Prostheses,Heart Valve Prostheses,Prostheses, Cardiac Valve,Prostheses, Heart Valve,Prosthesis, Cardiac Valve,Valve Prostheses, Cardiac,Valve Prostheses, Heart,Valve Prosthesis, Cardiac,Valve Prosthesis, Heart

Related Publications

M Jereczek, and B Levenson
November 2007, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
M Jereczek, and B Levenson
December 2004, Pacing and clinical electrophysiology : PACE,
M Jereczek, and B Levenson
March 2003, Heart (British Cardiac Society),
M Jereczek, and B Levenson
November 2020, Archivos de cardiologia de Mexico,
M Jereczek, and B Levenson
March 1991, Boletin de la Asociacion Medica de Puerto Rico,
M Jereczek, and B Levenson
June 2002, The New England journal of medicine,
M Jereczek, and B Levenson
December 2013, Anadolu kardiyoloji dergisi : AKD = the Anatolian journal of cardiology,
M Jereczek, and B Levenson
April 1985, Zeitschrift fur die gesamte innere Medizin und ihre Grenzgebiete,
M Jereczek, and B Levenson
January 1988, The American journal of cardiology,
M Jereczek, and B Levenson
April 1992, Pacing and clinical electrophysiology : PACE,
Copied contents to your clipboard!