Epicardial ventricular pacemaker electrode longevity in children. 1988

G A Serwer, and J M Mericle, and B E Armstrong
Department of Pediatrics, Duke University Medical Center, Durham, North Carolina.

While epicardially implanted electrodes remain the most widely used in children for ventricular pacing, their expected longevity remains unknown. The longevity of 126 such electrodes implanted from January 1970 through December 1985 was evaluated in 81 children followed up for 1 to 192 months (median 63). Age at initial implant was 1 day to 18 years. Each child had from 1 to 5 electrodes implanted; 85 electrodes were of the sutureless helical type and 41 were of the suture-fixated type. Electrode failure, defined as loss of capture with a high pacing threshold found at operation or sensing failure, occurred in 38 electrodes from 1 to 157 months postimplant (median 37). Mode of failure was high threshold with high impedance (n = 15), low impedance (n = 6), complete inability to pace (n = 8), sensing failure (n = 2) or high threshold with no measure of impedance (n = 7). Actuarial life table analysis of electrode longevity showed a 88 +/- 3% (standard error of the estimate) survival rate at 6 months with no significant decrease until 53 months (75 +/- 5%, p less than 0.05). There was then a gradual steady decrease to 49 +/- 7% by 101 months. From 101 to 157 months no significant decrease occurred. Survival rate decrease was greatest within the first 6 month period postimplant (-12%). Electrodes surviving to 6 months are highly likely to survive until 53 months. Of those surviving to 53 months, 74% should survive to 120 months.

UI MeSH Term Description Entries
D007223 Infant A child between 1 and 23 months of age. Infants
D007231 Infant, Newborn An infant during the first 28 days after birth. Neonate,Newborns,Infants, Newborn,Neonates,Newborn,Newborn Infant,Newborn Infants
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D002648 Child A person 6 to 12 years of age. An individual 2 to 5 years old is CHILD, PRESCHOOL. Children
D002675 Child, Preschool A child between the ages of 2 and 5. Children, Preschool,Preschool Child,Preschool Children
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D004868 Equipment Failure Failure of equipment to perform to standard. The failure may be due to defects or improper use. Defects, Equipment,Device Failure,Failure, Equipment,Malfunction, Equipment,Medical Device Failure,Misuse, Equipment,Device Failure, Medical,Device Failures, Medical,Failure, Medical Device,Failures, Medical Device,Defect, Equipment,Device Failures,Equipment Defect,Equipment Defects,Equipment Failures,Equipment Malfunction,Equipment Malfunctions,Equipment Misuse,Equipment Misuses,Failure, Device,Failures, Device,Failures, Equipment,Malfunctions, Equipment,Misuses, Equipment
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006343 Heart Septal Defects Abnormalities in any part of the HEART SEPTUM resulting in abnormal communication between the left and the right chambers of the heart. The abnormal blood flow inside the heart may be caused by defects in the ATRIAL SEPTUM, the VENTRICULAR SEPTUM, or both. Cardiac Septal Defect,Heart Septal Defect,Cardiac Septal Defects,Defect, Cardiac Septal,Defect, Heart Septal,Defects, Cardiac Septal,Defects, Heart Septal,Septal Defect, Cardiac,Septal Defect, Heart,Septal Defects, Cardiac,Septal Defects, Heart
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

G A Serwer, and J M Mericle, and B E Armstrong
March 2009, The Annals of thoracic surgery,
G A Serwer, and J M Mericle, and B E Armstrong
June 1974, Danish medical bulletin,
G A Serwer, and J M Mericle, and B E Armstrong
March 1981, Pacing and clinical electrophysiology : PACE,
G A Serwer, and J M Mericle, and B E Armstrong
July 2000, Pacing and clinical electrophysiology : PACE,
G A Serwer, and J M Mericle, and B E Armstrong
February 2014, The Thoracic and cardiovascular surgeon,
G A Serwer, and J M Mericle, and B E Armstrong
May 2015, HeartRhythm case reports,
G A Serwer, and J M Mericle, and B E Armstrong
March 1975, The Journal of thoracic and cardiovascular surgery,
G A Serwer, and J M Mericle, and B E Armstrong
September 1992, Zeitschrift fur Kardiologie,
G A Serwer, and J M Mericle, and B E Armstrong
December 1998, The Annals of thoracic surgery,
G A Serwer, and J M Mericle, and B E Armstrong
September 1989, Pacing and clinical electrophysiology : PACE,
Copied contents to your clipboard!