Establishment of transfer standard for holmium-166-DOTMP. 2004

J T Cessna, and B E Zimmerman, and M P Unterweger, and D B Golas
Ionizing Radiation Division, National Institute of Standards and Technology, 100 Bureau Drive Stop, 8462 Gaithersburg, MD 20899-8462, USA. jcessna@nist.gov

The measurement of 166Ho, both as a chloride solution and as [166Ho]-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetramethylenephoonic acid (DOTMP), was examined for four models of radionuclide calibrators: Capintec CRC-35R (two chambers), Capintec 712MX, AtomLab 100 (two chambers), and a Capintec CRC-12. Holmium-166 chloride was measured as 16 ml in 20-ml glass dose vials. Diagnostic imaging level [166Ho]DOTMP solutions, nominally 400 MBqg(-1), were measured as 12 ml in 20-ml dose vials. Finally, therapeutic level [166Ho]DOTMP solutions, nominally 9GBqg(-1), were measured as aliquots of 100-500 microl in sealed plastic vials of 10-ml saline. Single calibration factors for each instrument manufacturer are recommended for 12-16-ml of either solution in 20-ml glass dose vials, (673+/-9) x 10 and 72.7+/-0.7, for the Capintec and AtomLab models, respectively. Calibration factors recommended for the therapeutic dose geometry are (706+/-6) x 10 and 68.7+/-1.3, for the Capintec and AtomLab models, respectively. The calibration factors recommended for an NIST 5-ml ampoule are (686+/-5) x 10 and 70.9+/-0.4 for the Capintec and AtomLab models, respectively.

UI MeSH Term Description Entries
D009942 Organometallic Compounds A class of compounds of the type R-M, where a C atom is joined directly to any other element except H, C, N, O, F, Cl, Br, I, or At. (Grant & Hackh's Chemical Dictionary, 5th ed) Metallo-Organic Compound,Metallo-Organic Compounds,Metalloorganic Compound,Organometallic Compound,Metalloorganic Compounds,Compound, Metallo-Organic,Compound, Metalloorganic,Compound, Organometallic,Compounds, Metallo-Organic,Compounds, Metalloorganic,Compounds, Organometallic,Metallo Organic Compound,Metallo Organic Compounds
D009943 Organophosphorus Compounds Organic compounds that contain phosphorus as an integral part of the molecule. Included under this heading is broad array of synthetic compounds that are used as PESTICIDES and DRUGS. Organophosphorus Compound,Organopyrophosphorus Compound,Organopyrophosphorus Compounds,Compound, Organophosphorus,Compound, Organopyrophosphorus,Compounds, Organophosphorus,Compounds, Organopyrophosphorus
D011786 Quality Control A system for verifying and maintaining a desired level of quality in a product or process by careful planning, use of proper equipment, continued inspection, and corrective action as required. (Random House Unabridged Dictionary, 2d ed) Control, Quality,Controls, Quality,Quality Controls
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D012015 Reference Standards A basis of value established for the measure of quantity, weight, extent or quality, e.g. weight standards, standard solutions, methods, techniques, and procedures used in diagnosis and therapy. Standard Preparations,Standards, Reference,Preparations, Standard,Standardization,Standards,Preparation, Standard,Reference Standard,Standard Preparation,Standard, Reference
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D013048 Specimen Handling Procedures for collecting, preserving, and transporting of specimens sufficiently stable to provide accurate and precise results suitable for clinical interpretation. Specimen Collection,Collection, Specimen,Collections, Specimen,Handling, Specimen,Handlings, Specimen,Specimen Collections,Specimen Handlings
D014481 United States A country in NORTH AMERICA between CANADA and MEXICO.
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

J T Cessna, and B E Zimmerman, and M P Unterweger, and D B Golas
May 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
J T Cessna, and B E Zimmerman, and M P Unterweger, and D B Golas
October 2016, The British journal of radiology,
J T Cessna, and B E Zimmerman, and M P Unterweger, and D B Golas
April 1997, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine,
J T Cessna, and B E Zimmerman, and M P Unterweger, and D B Golas
January 2003, Nuclear medicine review. Central & Eastern Europe,
J T Cessna, and B E Zimmerman, and M P Unterweger, and D B Golas
November 2004, Clinical advances in hematology & oncology : H&O,
J T Cessna, and B E Zimmerman, and M P Unterweger, and D B Golas
May 2019, Seminars in nuclear medicine,
J T Cessna, and B E Zimmerman, and M P Unterweger, and D B Golas
July 2023, EJNMMI research,
J T Cessna, and B E Zimmerman, and M P Unterweger, and D B Golas
November 2002, Nuclear medicine and biology,
J T Cessna, and B E Zimmerman, and M P Unterweger, and D B Golas
March 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
Copied contents to your clipboard!