Stability of blood cell counts, hematologic parameters and reticulocytes indexes on the Advia A120 hematologic analyzer. 2005

Giuseppe Lippi, and Gian Luca Salvagno, and Gian Pietro Solero, and Massimo Franchini, and Gian Cesare Guidi
Sezione di Chimica e Microscopia Clinica, Dipartimento di Scienze Morfologico-Biomediche, Università degli Studi di Verona, Verona, Italy. ulippi@tin.it

Delayed sample analysis is not a rare circumstance in clinical and laboratory practice, especially when blood samples are shipped to distant centralized laboratories, when the analysis can not be readily performed, or when retesting is appropriate. In this study we sought to evaluate the stability of conventional and new hematologic parameters in blood specimens stored for as long as 24 hours at 4 degrees C. Of the 21 hematologic parameters tested with the use of the Advia 120 hematologic analyzer (Bayer Diagnostics), means for paired samples of specimens differed significantly over the 24-hour storage period for hematocrit, main corpuscular volume, percentage of macrocytes, platelet count, main platelet volume, reticulocyte count and percentage, and reticulocyte hemoglobin content (all P < .01). We noted no significant changes in the other parameters tested or in the white blood cell differential. The overall distribution of the immature reticulocytes fractions remained substantially unchanged, though the high staining-intensity fraction showed a considerable shift from the baseline measure. Bland-Altman plots and limits-of-agreement analysis showed mean biases between -4.8% and 37.2% and relative coefficients of variations ranging from 0.4% to 32.7%. The 95% agreement interval in the set of differences was satisfactory and almost within the current analytic-quality specifications for desirable bias. The results of this investigation suggest that, within certain limitations for parameters derived or calculated from cellular volumes, blood specimens stored for as long as 24 hours at 4 degrees C may be suitable for hematologic testing.

UI MeSH Term Description Entries
D008297 Male Males
D003080 Cold Temperature An absence of warmth or heat or a temperature notably below an accustomed norm. Cold,Cold Temperatures,Temperature, Cold,Temperatures, Cold
D006403 Hematologic Tests Tests used in the analysis of the hemic system. Blood Tests,Hematologic Test,Hematological Tests,Test, Hematologic,Tests, Hematologic,Blood Test,Hematological Test,Test, Blood,Test, Hematological,Tests, Blood,Tests, Hematological
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001331 Automation Controlled operation of an apparatus, process, or system by mechanical or electronic devices that take the place of human organs of observation, effort, and decision. (From Webster's Collegiate Dictionary, 1993) Automations
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D015510 Clinical Medicine The study and practice of medicine by direct examination of the patient. Medicine, Clinical

Related Publications

Giuseppe Lippi, and Gian Luca Salvagno, and Gian Pietro Solero, and Massimo Franchini, and Gian Cesare Guidi
April 2016, Practical laboratory medicine,
Giuseppe Lippi, and Gian Luca Salvagno, and Gian Pietro Solero, and Massimo Franchini, and Gian Cesare Guidi
September 2012, Journal of clinical laboratory analysis,
Giuseppe Lippi, and Gian Luca Salvagno, and Gian Pietro Solero, and Massimo Franchini, and Gian Cesare Guidi
June 2020, Veterinary clinical pathology,
Giuseppe Lippi, and Gian Luca Salvagno, and Gian Pietro Solero, and Massimo Franchini, and Gian Cesare Guidi
November 2013, Journal of clinical laboratory analysis,
Giuseppe Lippi, and Gian Luca Salvagno, and Gian Pietro Solero, and Massimo Franchini, and Gian Cesare Guidi
January 2005, Acta haematologica,
Giuseppe Lippi, and Gian Luca Salvagno, and Gian Pietro Solero, and Massimo Franchini, and Gian Cesare Guidi
June 2011, Veterinary clinical pathology,
Giuseppe Lippi, and Gian Luca Salvagno, and Gian Pietro Solero, and Massimo Franchini, and Gian Cesare Guidi
May 2018, Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc,
Giuseppe Lippi, and Gian Luca Salvagno, and Gian Pietro Solero, and Massimo Franchini, and Gian Cesare Guidi
September 2021, Annals of laboratory medicine,
Giuseppe Lippi, and Gian Luca Salvagno, and Gian Pietro Solero, and Massimo Franchini, and Gian Cesare Guidi
July 1981, American journal of clinical pathology,
Giuseppe Lippi, and Gian Luca Salvagno, and Gian Pietro Solero, and Massimo Franchini, and Gian Cesare Guidi
July 2023, Annals of clinical and laboratory science,
Copied contents to your clipboard!