Stability of BUN and creatinine determinations on the Siemens Advia 1800 analyzer. 2013

Jia Qin, and Huiying Wang, and Anton Rets, and Saul Harari, and Herol Alexis, and Ikram Eid, and Matthew R Pincus
Department of Pathology and Laboratory Medicine, NY Harbor VA Medical Center 800 Poly Place, Brooklyn, New York; Department of Pathology, SUNY Downstate Medical Center, Brooklyn, New York.

BACKGROUND Serum creatinine values of patients tend to change as a result of the use of different blanks used for creatinine determinations on the Advia 1650. After upgrading the analyzer to the Advia 1800, creatinine values tended to be more reproducible. As part of a quality assurance investigation to test the reproducibilities of creatinine values, we determined serial creatinine values in the sera of 13 patients whose initial values were either in the reference range or elevated (range 0.58-7.8 mg/dl). These values were determined concurrently with serum blood urea nitrogen (BUN) determinations (range 6.0-84.4 mg/dl) as these two analytes are used together in evaluation of renal function. METHODS We determined BUN and creatinine values, using the glutamate dehydrogenase lined enzyme assay system and the Jaffe method, respectively. RESULTS We find that all values for creatinine on samples stored at 4 °C were reproducible as were the corresponding BUN values, which is revealed by low values for the coefficients of variation (CVs), that is, mean CV of 4.55% for creatinine and 2.52% for BUN. One sample with relatively high CV (10.6%) for creatinine was found to have an initial value of 1.1 mg/dl, in the reference range; but, on repeat determinations, the obtained levels were as high as 1.5 mg/dl, above the reference range. BUN values for this sample remained in the reference range, suggesting that no renal disease was present. CONCLUSIONS We conclude that creatinine and BUN determinations are stable, but occasional spurious creatinine values can occur on the Advia 1800 analyzer.

UI MeSH Term Description Entries
D001774 Blood Chemical Analysis An examination of chemicals in the blood. Analysis, Blood Chemical,Chemical Analysis, Blood,Analyses, Blood Chemical,Blood Chemical Analyses,Chemical Analyses, Blood
D001806 Blood Urea Nitrogen The urea concentration of the blood stated in terms of nitrogen content. Serum (plasma) urea nitrogen is approximately 12% higher than blood urea nitrogen concentration because of the greater protein content of red blood cells. Increases in blood or serum urea nitrogen are referred to as azotemia and may have prerenal, renal, or postrenal causes. (From Saunders Dictionary & Encyclopedia of Laboratory Medicine and Technology, 1984) BUN,Nitrogen, Blood Urea,Urea Nitrogen, Blood
D003404 Creatinine Creatinine Sulfate Salt,Krebiozen,Salt, Creatinine Sulfate,Sulfate Salt, Creatinine
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D014508 Urea A compound formed in the liver from ammonia produced by the deamination of amino acids. It is the principal end product of protein catabolism and constitutes about one half of the total urinary solids. Basodexan,Carbamide,Carmol
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

Jia Qin, and Huiying Wang, and Anton Rets, and Saul Harari, and Herol Alexis, and Ikram Eid, and Matthew R Pincus
September 2012, Journal of clinical laboratory analysis,
Jia Qin, and Huiying Wang, and Anton Rets, and Saul Harari, and Herol Alexis, and Ikram Eid, and Matthew R Pincus
January 2017, Journal of clinical laboratory analysis,
Jia Qin, and Huiying Wang, and Anton Rets, and Saul Harari, and Herol Alexis, and Ikram Eid, and Matthew R Pincus
May 2019, Journal of clinical laboratory analysis,
Jia Qin, and Huiying Wang, and Anton Rets, and Saul Harari, and Herol Alexis, and Ikram Eid, and Matthew R Pincus
February 2015, Clinical biochemistry,
Jia Qin, and Huiying Wang, and Anton Rets, and Saul Harari, and Herol Alexis, and Ikram Eid, and Matthew R Pincus
October 1990, Clinical chemistry,
Jia Qin, and Huiying Wang, and Anton Rets, and Saul Harari, and Herol Alexis, and Ikram Eid, and Matthew R Pincus
September 1989, Clinical pharmacy,
Jia Qin, and Huiying Wang, and Anton Rets, and Saul Harari, and Herol Alexis, and Ikram Eid, and Matthew R Pincus
March 2019, Clinica chimica acta; international journal of clinical chemistry,
Jia Qin, and Huiying Wang, and Anton Rets, and Saul Harari, and Herol Alexis, and Ikram Eid, and Matthew R Pincus
December 2005, The Journal of laboratory and clinical medicine,
Jia Qin, and Huiying Wang, and Anton Rets, and Saul Harari, and Herol Alexis, and Ikram Eid, and Matthew R Pincus
April 2016, Practical laboratory medicine,
Jia Qin, and Huiying Wang, and Anton Rets, and Saul Harari, and Herol Alexis, and Ikram Eid, and Matthew R Pincus
March 2015, Journal of diabetes science and technology,
Copied contents to your clipboard!