Rate responsive pacing with a minute ventilation sensing pacemaker during pregnancy and delivery. 1990

C P Lau, and C P Lee, and C K Wong, and C H Cheng, and W H Leung
Department of Medicine, University of Hong Kong, Queen Mary Hospital.

A minute ventilation sensing rate responsive pacemaker was implanted in a 29-week pregnant woman with symptomatic complete atrioventricular (AV) block under echocardiographic and electrocardiographic (ECG) guidance. Satisfactory rate responses during a submaximal treadmill exercise test and daily activities were achieved. The course of pregnancy and cesarean section is discussed. During the cesarean section and after the delivery of the baby, changes in the ventilator settings confirmed that the pacing rate was closely correlated with both the tidal volume (r = 0.94, P less than 0.01) and the respiratory rate (r = 0.93, P less than 0.05).

UI MeSH Term Description Entries
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D011247 Pregnancy The status during which female mammals carry their developing young (EMBRYOS or FETUSES) in utero before birth, beginning from FERTILIZATION to BIRTH. Gestation,Pregnancies
D011248 Pregnancy Complications Conditions or pathological processes associated with pregnancy. They can occur during or after pregnancy, and range from minor discomforts to serious diseases that require medical interventions. They include diseases in pregnant females, and pregnancies in females with diseases. Adverse Birth Outcomes,Complications, Pregnancy,Adverse Birth Outcome,Birth Outcome, Adverse,Complication, Pregnancy,Outcome, Adverse Birth,Pregnancy Complication
D011296 Prenatal Diagnosis Determination of the nature of a pathological condition or disease in the postimplantation EMBRYO; FETUS; or pregnant female before birth. Diagnosis, Prenatal,Fetal Diagnosis,Fetal Imaging,Fetal Screening,Intrauterine Diagnosis,Antenatal Diagnosis,Antenatal Screening,Diagnosis, Antenatal,Diagnosis, Intrauterine,Prenatal Screening,Antenatal Diagnoses,Antenatal Screenings,Diagnosis, Fetal,Fetal Diagnoses,Fetal Imagings,Fetal Screenings,Imaging, Fetal,Intrauterine Diagnoses,Prenatal Diagnoses,Prenatal Screenings,Screening, Antenatal,Screening, Fetal,Screening, Prenatal
D012119 Respiration The act of breathing with the LUNGS, consisting of INHALATION, or the taking into the lungs of the ambient air, and of EXHALATION, or the expelling of the modified air which contains more CARBON DIOXIDE than the air taken in (Blakiston's Gould Medical Dictionary, 4th ed.). This does not include tissue respiration ( Breathing
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D002585 Cesarean Section Extraction of the FETUS by means of abdominal HYSTEROTOMY. Abdominal Delivery,Delivery, Abdominal,C-Section (OB),Caesarean Section,Postcesarean Section,Abdominal Deliveries,C Section (OB),C-Sections (OB),Caesarean Sections,Cesarean Sections,Deliveries, Abdominal
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005082 Physical Exertion Expenditure of energy during PHYSICAL ACTIVITY. Intensity of exertion may be measured by rate of OXYGEN CONSUMPTION; HEAT produced, or HEART RATE. Perceived exertion, a psychological measure of exertion, is included. Physical Effort,Effort, Physical,Efforts, Physical,Exertion, Physical,Exertions, Physical,Physical Efforts,Physical Exertions

Related Publications

C P Lau, and C P Lee, and C K Wong, and C H Cheng, and W H Leung
November 1988, Pacing and clinical electrophysiology : PACE,
C P Lau, and C P Lee, and C K Wong, and C H Cheng, and W H Leung
June 2001, Pacing and clinical electrophysiology : PACE,
C P Lau, and C P Lee, and C K Wong, and C H Cheng, and W H Leung
September 1995, Orvosi hetilap,
C P Lau, and C P Lee, and C K Wong, and C H Cheng, and W H Leung
August 1993, Pacing and clinical electrophysiology : PACE,
C P Lau, and C P Lee, and C K Wong, and C H Cheng, and W H Leung
October 2005, Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing,
C P Lau, and C P Lee, and C K Wong, and C H Cheng, and W H Leung
February 1989, Pacing and clinical electrophysiology : PACE,
C P Lau, and C P Lee, and C K Wong, and C H Cheng, and W H Leung
March 2006, Pacing and clinical electrophysiology : PACE,
C P Lau, and C P Lee, and C K Wong, and C H Cheng, and W H Leung
August 1994, Pacing and clinical electrophysiology : PACE,
C P Lau, and C P Lee, and C K Wong, and C H Cheng, and W H Leung
October 2006, Pacing and clinical electrophysiology : PACE,
C P Lau, and C P Lee, and C K Wong, and C H Cheng, and W H Leung
December 1989, Pacing and clinical electrophysiology : PACE,
Copied contents to your clipboard!