Rate responsive cardiac pacing using a minute ventilation sensor. 1993

A M Abrahamsen, and S Barvik, and T Aarsland, and K Dickstein
Medical Department, Central Hospital, Rogaland, Stavanger, Norway.

A minute ventilation sensing rate responsive pacemaker was implanted in 15 patients (8 males and 7 females) with bradycardia. The mean age was 72.8 +/- 8.7 years. The single chamber system measures transthoracic impedance between the tip electrode of a standard bipolar lead and the pulse generator case. In the adaptive mode the pulse generator calculates a rate responsive factor or slope during maximal exercise but functions as in the VVI mode. The patients exercised maximally on an upright cycle ergometer with the pacemaker programmed to VVI mode, adaptive mode, and rate responsive mode. Exercise and gas exchange data were collected continuously and analyzed using an automated breath-by-breath system. The slope, heart rate, and ventilation were measured every 20 seconds. Heart rate in pacemaker dependent patients correlated well to minute ventilation (correlation coefficient ranging from 0.72-0.95, P < 0.0001). This study demonstrates that minute ventilation is a good metabolic sensor in rate responsive pacing.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D011659 Pulmonary Gas Exchange The exchange of OXYGEN and CARBON DIOXIDE between alveolar air and pulmonary capillary blood that occurs across the BLOOD-AIR BARRIER. Exchange, Pulmonary Gas,Gas Exchange, Pulmonary
D012119 Respiration The act of breathing with the LUNGS, consisting of INHALATION, or the taking into the lungs of the ambient air, and of EXHALATION, or the expelling of the modified air which contains more CARBON DIOXIDE than the air taken in (Blakiston's Gould Medical Dictionary, 4th ed.). This does not include tissue respiration ( Breathing
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D004582 Electronics, Medical The research and development of ELECTRICAL EQUIPMENT AND SUPPLIES for such medical applications as diagnosis, therapy, research, anesthesia control, cardiac control, and surgery. (From McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Medical Electronics
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D005082 Physical Exertion Expenditure of energy during PHYSICAL ACTIVITY. Intensity of exertion may be measured by rate of OXYGEN CONSUMPTION; HEAT produced, or HEART RATE. Perceived exertion, a psychological measure of exertion, is included. Physical Effort,Effort, Physical,Efforts, Physical,Exertion, Physical,Exertions, Physical,Physical Efforts,Physical Exertions

Related Publications

A M Abrahamsen, and S Barvik, and T Aarsland, and K Dickstein
November 1988, Pacing and clinical electrophysiology : PACE,
A M Abrahamsen, and S Barvik, and T Aarsland, and K Dickstein
December 1990, Pacing and clinical electrophysiology : PACE,
A M Abrahamsen, and S Barvik, and T Aarsland, and K Dickstein
February 1989, Pacing and clinical electrophysiology : PACE,
A M Abrahamsen, and S Barvik, and T Aarsland, and K Dickstein
December 2002, Pacing and clinical electrophysiology : PACE,
A M Abrahamsen, and S Barvik, and T Aarsland, and K Dickstein
February 1990, Pacing and clinical electrophysiology : PACE,
A M Abrahamsen, and S Barvik, and T Aarsland, and K Dickstein
December 1990, Annales de cardiologie et d'angeiologie,
A M Abrahamsen, and S Barvik, and T Aarsland, and K Dickstein
August 1989, Pacing and clinical electrophysiology : PACE,
A M Abrahamsen, and S Barvik, and T Aarsland, and K Dickstein
June 2001, Pacing and clinical electrophysiology : PACE,
A M Abrahamsen, and S Barvik, and T Aarsland, and K Dickstein
February 1997, Pacing and clinical electrophysiology : PACE,
A M Abrahamsen, and S Barvik, and T Aarsland, and K Dickstein
July 1993, Orvosi hetilap,
Copied contents to your clipboard!