Improved biocompatibility of extracorporeal circulation by the use of auto-oxygenation instead of artificial oxygenator in perfusion circuit. 1991

A Bochenek, and Z Religa, and R Kustosz, and A M Wnuk-Wojnar, and R Wnuk, and J Wojnar, and S Woś, and M Wites, and M Zembala, and T Spyt
Cardiothoracic Surgery Department, Silesian Heart Center, Katowice, Poland.

The aim of this study was to determine the biocompatibility of an auto-oxygenation technique of cardiopulmonary bypass. Forty patients undergoing coronary bypass surgery were studied in two groups: A (auto-oxygenation, patients' lungs used in cardiopulmonary bypass) and B (conventional technique of cardiopulmonary bypass with bubble oxygenator). The platelet count decreased to -73% of initial value in group B vs only -27% in group A, P less than 0.001. Platelet aggregation to ADP decreased slightly in group A and hardly at all in group B, P less than 0.001. A transpulmonary leukocyte sequestration was greater in group B: 1.46 +/- 0.5 x 10(3)/mm3 vs only 0.34 +/- 0.2 x 10(3)/mm3 in group A, P less than 0.001. The level of C3a increased in group A from 244 +/- 46 ng/ml to 418 +/- 34 ng/ml and in group B from 268 +/- 46 ng/ml to 521 +/- 65 ng/ml, P less than 0.001, but in group A the levels were significantly less, P less than 0.001. The current study clearly confirms the superior biocompatibility of cardiopulmonary bypass with lung over oxygenator.

UI MeSH Term Description Entries
D007958 Leukocyte Count The number of WHITE BLOOD CELLS per unit volume in venous BLOOD. A differential leukocyte count measures the relative numbers of the different types of white cells. Blood Cell Count, White,Differential Leukocyte Count,Leukocyte Count, Differential,Leukocyte Number,White Blood Cell Count,Count, Differential Leukocyte,Count, Leukocyte,Counts, Differential Leukocyte,Counts, Leukocyte,Differential Leukocyte Counts,Leukocyte Counts,Leukocyte Counts, Differential,Leukocyte Numbers,Number, Leukocyte,Numbers, Leukocyte
D008422 Materials Testing The testing of materials and devices, especially those used for PROSTHESES AND IMPLANTS; SUTURES; TISSUE ADHESIVES; etc., for hardness, strength, durability, safety, efficacy, and biocompatibility. Biocompatibility Testing,Biocompatible Materials Testing,Hemocompatibility Testing,Testing, Biocompatible Materials,Testing, Hemocompatible Materials,Hemocompatibility Testings,Hemocompatible Materials Testing,Materials Testing, Biocompatible,Materials Testing, Hemocompatible,Testing, Biocompatibility,Testing, Hemocompatibility,Testing, Materials,Testings, Biocompatibility
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010106 Oxygenators Devices which mechanically oxygenate venous blood extracorporeally. They are used in combination with one or more pumps for maintaining circulation during open heart surgery and for assisting the circulation in patients seriously ill with some cardiac and pulmonary disorders. (UMDNS, 1999) Oxygenator
D010976 Platelet Count The number of PLATELETS per unit volume in a sample of venous BLOOD. Blood Platelet Count,Blood Platelet Number,Platelet Number,Blood Platelet Counts,Blood Platelet Numbers,Count, Blood Platelet,Count, Platelet,Counts, Blood Platelet,Counts, Platelet,Number, Blood Platelet,Number, Platelet,Numbers, Blood Platelet,Numbers, Platelet,Platelet Count, Blood,Platelet Counts,Platelet Counts, Blood,Platelet Number, Blood,Platelet Numbers,Platelet Numbers, Blood
D001760 Bleeding Time Duration of blood flow after skin puncture. This test is used as a measure of capillary and platelet function. Aspirin Tolerance Test,Bleeding Time, Template,Duke Method,Ivy Method,Template Bleeding Time,Aspirin Tolerance Tests,Bleeding Times,Bleeding Times, Template,Method, Duke,Method, Ivy,Template Bleeding Times,Test, Aspirin Tolerance,Tests, Aspirin Tolerance,Time, Bleeding,Time, Template Bleeding,Times, Bleeding,Times, Template Bleeding,Tolerance Test, Aspirin,Tolerance Tests, Aspirin
D001792 Blood Platelets Non-nucleated disk-shaped cells formed in the megakaryocyte and found in the blood of all mammals. They are mainly involved in blood coagulation. Platelets,Thrombocytes,Blood Platelet,Platelet,Platelet, Blood,Platelets, Blood,Thrombocyte
D002315 Cardiopulmonary Bypass Diversion of the flow of blood from the entrance of the right atrium directly to the aorta (or femoral artery) via an oxygenator thus bypassing both the heart and lungs. Heart-Lung Bypass,Bypass, Cardiopulmonary,Bypass, Heart-Lung,Bypasses, Cardiopulmonary,Bypasses, Heart-Lung,Cardiopulmonary Bypasses,Heart Lung Bypass,Heart-Lung Bypasses
D003167 Complement Activation The sequential activation of serum COMPLEMENT PROTEINS to create the COMPLEMENT MEMBRANE ATTACK COMPLEX. Factors initiating complement activation include ANTIGEN-ANTIBODY COMPLEXES, microbial ANTIGENS, or cell surface POLYSACCHARIDES. Activation, Complement,Activations, Complement,Complement Activations
D005112 Extracorporeal Circulation Diversion of blood flow through a circuit located outside the body but continuous with the bodily circulation. Circulation, Extracorporeal,Circulations, Extracorporeal,Extracorporeal Circulations

Related Publications

A Bochenek, and Z Religa, and R Kustosz, and A M Wnuk-Wojnar, and R Wnuk, and J Wojnar, and S Woś, and M Wites, and M Zembala, and T Spyt
January 1990, Anesteziologiia i reanimatologiia,
A Bochenek, and Z Religa, and R Kustosz, and A M Wnuk-Wojnar, and R Wnuk, and J Wojnar, and S Woś, and M Wites, and M Zembala, and T Spyt
January 2015, ASAIO journal (American Society for Artificial Internal Organs : 1992),
A Bochenek, and Z Religa, and R Kustosz, and A M Wnuk-Wojnar, and R Wnuk, and J Wojnar, and S Woś, and M Wites, and M Zembala, and T Spyt
February 1990, Rozhledy v chirurgii : mesicnik Ceskoslovenske chirurgicke spolecnosti,
A Bochenek, and Z Religa, and R Kustosz, and A M Wnuk-Wojnar, and R Wnuk, and J Wojnar, and S Woś, and M Wites, and M Zembala, and T Spyt
April 1980, The Journal of thoracic and cardiovascular surgery,
A Bochenek, and Z Religa, and R Kustosz, and A M Wnuk-Wojnar, and R Wnuk, and J Wojnar, and S Woś, and M Wites, and M Zembala, and T Spyt
October 1952, Journal of the American Medical Association,
A Bochenek, and Z Religa, and R Kustosz, and A M Wnuk-Wojnar, and R Wnuk, and J Wojnar, and S Woś, and M Wites, and M Zembala, and T Spyt
May 1960, Helvetica chirurgica acta,
A Bochenek, and Z Religa, and R Kustosz, and A M Wnuk-Wojnar, and R Wnuk, and J Wojnar, and S Woś, and M Wites, and M Zembala, and T Spyt
January 1990, Vestnik Akademii meditsinskikh nauk SSSR,
A Bochenek, and Z Religa, and R Kustosz, and A M Wnuk-Wojnar, and R Wnuk, and J Wojnar, and S Woś, and M Wites, and M Zembala, and T Spyt
April 1991, The Journal of thoracic and cardiovascular surgery,
A Bochenek, and Z Religa, and R Kustosz, and A M Wnuk-Wojnar, and R Wnuk, and J Wojnar, and S Woś, and M Wites, and M Zembala, and T Spyt
January 1975, Transactions - American Society for Artificial Internal Organs,
A Bochenek, and Z Religa, and R Kustosz, and A M Wnuk-Wojnar, and R Wnuk, and J Wojnar, and S Woś, and M Wites, and M Zembala, and T Spyt
September 1961, British medical journal,
Copied contents to your clipboard!