Effects of pulsed, spatially fractionated, microscopic synchrotron X-ray beams on normal and tumoral brain tissue. 2010

E Bräuer-Krisch, and R Serduc, and E A Siegbahn, and G Le Duc, and Y Prezado, and A Bravin, and H Blattmann, and J A Laissue
European Synchrotron Radiation Facility, B.P. 220, 38043 Grenoble, France. brauer@esrf.fr

Microbeam radiation therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600keV, produced by third generation synchrotron sources, such as the European Synchrotron Radiation Facility (ESRF), in France. The main advantages of highly brilliant synchrotron sources are an extremely high dose rate and very small beam divergence. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. The minimal beam divergence results in the advantage of steeper dose gradients delivered to a tumor target, thus achieving a higher dose deposition in the target volume in fractions of seconds, with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has yielded many results from preclinical trials based on different animal models, including mice, rats, piglets and rabbits. Typically, MRT uses arrays of narrow ( approximately 25-100 microm wide) microplanar beams separated by wider (100-400 microm centre-to-centre) microplanar spaces. The height of these microbeams typically varies from 1 to 100 mm, depending on the target and the desired preselected field size to be irradiated. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues, up to approximately 2 yr after irradiation, and at the same time show a preferential damage of malignant tumor tissues; these effects of MRT have now been extensively studied over nearly two decades. More recently, some biological in vivo effects of synchrotron X-ray beams in the millimeter range (0.68-0.95 mm, centre-to-centre distances 1.2-4 mm), which may differ to some extent from those of microscopic beams, have been followed up to approximately 7 months after irradiation. Comparisons between broad-beam irradiation and MRT indicate a higher tumor control for the same sparing of normal tissue in the latter, even if a substantial fraction of tumor cells are not receiving a radiotoxic level of radiation. The hypothesis of a selective radiovulnerability of the tumor vasculature versus normal blood vessels by MRT, and of the cellular and molecular mechanisms involved remains under investigation. The paper highlights the history of MRT including salient biological findings after microbeam irradiation with emphasis on the vascular components and the tolerance of the central nervous system. Details on experimental and theoretical dosimetry of microbeams, core issues and possible therapeutic applications of MRT are presented.

UI MeSH Term Description Entries
D009369 Neoplasms New abnormal growth of tissue. Malignant neoplasms show a greater degree of anaplasia and have the properties of invasion and metastasis, compared to benign neoplasms. Benign Neoplasm,Cancer,Malignant Neoplasm,Tumor,Tumors,Benign Neoplasms,Malignancy,Malignant Neoplasms,Neoplasia,Neoplasm,Neoplasms, Benign,Cancers,Malignancies,Neoplasias,Neoplasm, Benign,Neoplasm, Malignant,Neoplasms, Malignant
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D011878 Radiotherapy The use of IONIZING RADIATION to treat malignant NEOPLASMS and some benign conditions. Radiotherapy, Targeted,Targeted Radiotherapy,Radiation Therapy,Radiation Therapy, Targeted,Radiation Treatment,Targeted Radiation Therapy,Radiation Therapies,Radiation Therapies, Targeted,Radiation Treatments,Radiotherapies,Radiotherapies, Targeted,Targeted Radiation Therapies,Targeted Radiotherapies,Therapies, Radiation,Therapies, Targeted Radiation,Therapy, Radiation,Therapy, Targeted Radiation,Treatment, Radiation
D001808 Blood Vessels Any of the tubular vessels conveying the blood (arteries, arterioles, capillaries, venules, and veins). Blood Vessel,Vessel, Blood,Vessels, Blood
D001921 Brain The part of CENTRAL NERVOUS SYSTEM that is contained within the skull (CRANIUM). Arising from the NEURAL TUBE, the embryonic brain is comprised of three major parts including PROSENCEPHALON (the forebrain); MESENCEPHALON (the midbrain); and RHOMBENCEPHALON (the hindbrain). The developed brain consists of CEREBRUM; CEREBELLUM; and other structures in the BRAIN STEM. Encephalon
D001932 Brain Neoplasms Neoplasms of the intracranial components of the central nervous system, including the cerebral hemispheres, basal ganglia, hypothalamus, thalamus, brain stem, and cerebellum. Brain neoplasms are subdivided into primary (originating from brain tissue) and secondary (i.e., metastatic) forms. Primary neoplasms are subdivided into benign and malignant forms. In general, brain tumors may also be classified by age of onset, histologic type, or presenting location in the brain. Brain Cancer,Brain Metastases,Brain Tumors,Cancer of Brain,Malignant Primary Brain Tumors,Neoplasms, Intracranial,Benign Neoplasms, Brain,Brain Neoplasm, Primary,Brain Neoplasms, Benign,Brain Neoplasms, Malignant,Brain Neoplasms, Malignant, Primary,Brain Neoplasms, Primary Malignant,Brain Tumor, Primary,Brain Tumor, Recurrent,Cancer of the Brain,Intracranial Neoplasms,Malignant Neoplasms, Brain,Malignant Primary Brain Neoplasms,Neoplasms, Brain,Neoplasms, Brain, Benign,Neoplasms, Brain, Malignant,Neoplasms, Brain, Primary,Primary Brain Neoplasms,Primary Malignant Brain Neoplasms,Primary Malignant Brain Tumors,Benign Brain Neoplasm,Benign Brain Neoplasms,Benign Neoplasm, Brain,Brain Benign Neoplasm,Brain Benign Neoplasms,Brain Cancers,Brain Malignant Neoplasm,Brain Malignant Neoplasms,Brain Metastase,Brain Neoplasm,Brain Neoplasm, Benign,Brain Neoplasm, Malignant,Brain Neoplasms, Primary,Brain Tumor,Brain Tumors, Recurrent,Cancer, Brain,Intracranial Neoplasm,Malignant Brain Neoplasm,Malignant Brain Neoplasms,Malignant Neoplasm, Brain,Neoplasm, Brain,Neoplasm, Intracranial,Primary Brain Neoplasm,Primary Brain Tumor,Primary Brain Tumors,Recurrent Brain Tumor,Recurrent Brain Tumors,Tumor, Brain
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D013679 Technology, Radiologic The application of scientific knowledge or technology to the field of radiology. The applications center mostly around x-ray or radioisotopes for diagnostic and therapeutic purposes but the technological applications of any radiation or radiologic procedure is within the scope of radiologic technology. Radiologic Technology,Technology, Radiological,Radiological Technology
D014965 X-Rays Penetrating electromagnetic radiation emitted when the inner orbital electrons of an atom are excited and release radiant energy. X-ray wavelengths range from 1 pm to 10 nm. Hard X-rays are the higher energy, shorter wavelength X-rays. Soft x-rays or Grenz rays are less energetic and longer in wavelength. The short wavelength end of the X-ray spectrum overlaps the GAMMA RAYS wavelength range. The distinction between gamma rays and X-rays is based on their radiation source. Grenz Ray,Grenz Rays,Roentgen Ray,Roentgen Rays,X Ray,X-Ray,Xray,Radiation, X,X-Radiation,Xrays,Ray, Grenz,Ray, Roentgen,Ray, X,Rays, Grenz,Rays, Roentgen,Rays, X,X Radiation,X Rays,X-Radiations

Related Publications

E Bräuer-Krisch, and R Serduc, and E A Siegbahn, and G Le Duc, and Y Prezado, and A Bravin, and H Blattmann, and J A Laissue
October 2001, Nature,
E Bräuer-Krisch, and R Serduc, and E A Siegbahn, and G Le Duc, and Y Prezado, and A Bravin, and H Blattmann, and J A Laissue
July 2016, Medical physics,
E Bräuer-Krisch, and R Serduc, and E A Siegbahn, and G Le Duc, and Y Prezado, and A Bravin, and H Blattmann, and J A Laissue
January 1953, Cancer research,
E Bräuer-Krisch, and R Serduc, and E A Siegbahn, and G Le Duc, and Y Prezado, and A Bravin, and H Blattmann, and J A Laissue
January 2008, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry,
E Bräuer-Krisch, and R Serduc, and E A Siegbahn, and G Le Duc, and Y Prezado, and A Bravin, and H Blattmann, and J A Laissue
July 2008, The Review of scientific instruments,
E Bräuer-Krisch, and R Serduc, and E A Siegbahn, and G Le Duc, and Y Prezado, and A Bravin, and H Blattmann, and J A Laissue
July 2018, International journal of radiation oncology, biology, physics,
E Bräuer-Krisch, and R Serduc, and E A Siegbahn, and G Le Duc, and Y Prezado, and A Bravin, and H Blattmann, and J A Laissue
October 2023, Medical physics,
E Bräuer-Krisch, and R Serduc, and E A Siegbahn, and G Le Duc, and Y Prezado, and A Bravin, and H Blattmann, and J A Laissue
August 2015, The Review of scientific instruments,
E Bräuer-Krisch, and R Serduc, and E A Siegbahn, and G Le Duc, and Y Prezado, and A Bravin, and H Blattmann, and J A Laissue
April 2014, Nanomedicine : nanotechnology, biology, and medicine,
E Bräuer-Krisch, and R Serduc, and E A Siegbahn, and G Le Duc, and Y Prezado, and A Bravin, and H Blattmann, and J A Laissue
January 2014, Journal of synchrotron radiation,
Copied contents to your clipboard!