Off-pump transapical mitral valve-in-ring implantation. 2013

Yu Zou, and Enrico Ferrari, and Ludwig K von Segesser
Department of Cardiac Surgery, The First Affiliated Hospital of Medical College, Zhejiang University, Hangzhou, China. zou123123yu@163.com

OBJECTIVE The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM™). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT™) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.

UI MeSH Term Description Entries
D008943 Mitral Valve The valve between the left atrium and left ventricle of the heart. Bicuspid Valve,Bicuspid Valves,Mitral Valves,Valve, Bicuspid,Valve, Mitral,Valves, Bicuspid,Valves, Mitral
D008944 Mitral Valve Insufficiency Backflow of blood from the LEFT VENTRICLE into the LEFT ATRIUM due to imperfect closure of the MITRAL VALVE. This can lead to mitral valve regurgitation. Mitral Incompetence,Mitral Regurgitation,Mitral Valve Incompetence,Mitral Insufficiency,Mitral Valve Regurgitation,Incompetence, Mitral,Incompetence, Mitral Valve,Insufficiency, Mitral,Insufficiency, Mitral Valve,Regurgitation, Mitral,Regurgitation, Mitral Valve,Valve Incompetence, Mitral,Valve Insufficiency, Mitral,Valve Regurgitation, Mitral
D005260 Female Females
D006328 Cardiac Catheterization Procedures in which placement of CARDIAC CATHETERS is performed for therapeutic or diagnostic procedures. Catheterization, Cardiac,Catheterization, Heart,Heart Catheterization,Cardiac Catheterizations,Catheterizations, Cardiac,Catheterizations, Heart,Heart Catheterizations
D006350 Heart Valve Prosthesis A device that substitutes for a heart valve. It may be composed of biological material (BIOPROSTHESIS) and/or synthetic material. Prosthesis, Heart Valve,Cardiac Valve Prosthesis,Cardiac Valve Prostheses,Heart Valve Prostheses,Prostheses, Cardiac Valve,Prostheses, Heart Valve,Prosthesis, Cardiac Valve,Valve Prostheses, Cardiac,Valve Prostheses, Heart,Valve Prosthesis, Cardiac,Valve Prosthesis, Heart
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D013552 Swine Any of various animals that constitute the family Suidae and comprise stout-bodied, short-legged omnivorous mammals with thick skin, usually covered with coarse bristles, a rather long mobile snout, and small tail. Included are the genera Babyrousa, Phacochoerus (wart hogs), and Sus, the latter containing the domestic pig (see SUS SCROFA). Phacochoerus,Pigs,Suidae,Warthogs,Wart Hogs,Hog, Wart,Hogs, Wart,Wart Hog
D015607 Stents Devices that provide support for tubular structures that are being anastomosed or for body cavities during skin grafting. Stent
D058386 Mitral Valve Annuloplasty A type of heart valve surgery that involves the repair, replacement, or reconstruction of the annulus of the MITRAL VALVE. It includes shortening the circumference of the annulus to improve valve closing capacity and reinforcing the annulus as a step in more complex valve repairs. Mitral Annuloplasty,Mitral Valve Annulus Repair,Annuloplasties, Mitral,Annuloplasties, Mitral Valve,Annuloplasty, Mitral,Annuloplasty, Mitral Valve,Mitral Annuloplasties,Mitral Valve Annuloplasties,Valve Annuloplasties, Mitral,Valve Annuloplasty, Mitral
D019918 Heart Valve Prosthesis Implantation Surgical insertion of synthetic material to repair injured or diseased heart valves. Implantation, Heart Valve Prosthesis

Related Publications

Yu Zou, and Enrico Ferrari, and Ludwig K von Segesser
July 2009, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery,
Yu Zou, and Enrico Ferrari, and Ludwig K von Segesser
March 2021, Current opinion in cardiology,
Yu Zou, and Enrico Ferrari, and Ludwig K von Segesser
January 2010, Multimedia manual of cardiothoracic surgery : MMCTS,
Yu Zou, and Enrico Ferrari, and Ludwig K von Segesser
April 2019, The Annals of thoracic surgery,
Yu Zou, and Enrico Ferrari, and Ludwig K von Segesser
January 2018, Technology and health care : official journal of the European Society for Engineering and Medicine,
Yu Zou, and Enrico Ferrari, and Ludwig K von Segesser
April 2021, Journal of cardiac surgery,
Yu Zou, and Enrico Ferrari, and Ludwig K von Segesser
December 2021, Revista portuguesa de cardiologia,
Yu Zou, and Enrico Ferrari, and Ludwig K von Segesser
December 2016, Journal of cardiothoracic and vascular anesthesia,
Yu Zou, and Enrico Ferrari, and Ludwig K von Segesser
February 2016, International journal of cardiology,
Yu Zou, and Enrico Ferrari, and Ludwig K von Segesser
November 2017, JACC. Cardiovascular imaging,
Copied contents to your clipboard!