Clinical trial of the disposable transducer catheter. 1988

S D Cha, and C F Roman, and V Maranhao
Department of Cardiology, Deborah Heart and Lung Center, Browns Mills, NJ 08015.

We compared the intracardiac and intravascular pressures obtained by a conventional strain gauge transducer (CT) with a recently developed disposable high-fidelity transducer catheter (DT) during cardiac catheterization. CT was positioned at the patient's midchest level. The pressure measurements obtained by DT compared favorably with those of CT. Femoral arterial pressures by the two methods showed no statistical difference. Right heart pressures were similar using both transducers. However, right ventricular pressures by DT in five of eight patients were lower than that from CT. Higher pulmonary arterial pressures were noted in two of seven patients and higher pulmonary capillary wedge pressures were seen in four patients using DT compared to CT. None of these differences were of statistical significance. These pressure differences may be due to transducer position. Because the midchest position of CT does not precisely define the anatomic location of the cardiac chamber being studied, pressure measurements can be overestimated or underestimated. DT eliminates this problem, as well as overshooting and concern with air bubbles in the catheter system commonly associated with CT. Therefore DT may provide accurate hemodynamic measurements. It would appear to be useful regardless of patient position and may be useful in ambulatory hemodynamic determinations.

UI MeSH Term Description Entries
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D004209 Disposable Equipment Apparatus, devices, or supplies intended for one-time or temporary use. Equipment, Disposable
D006328 Cardiac Catheterization Procedures in which placement of CARDIAC CATHETERS is performed for therapeutic or diagnostic procedures. Catheterization, Cardiac,Catheterization, Heart,Heart Catheterization,Cardiac Catheterizations,Catheterizations, Cardiac,Catheterizations, Heart,Heart Catheterizations
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D014159 Transducers Any device or element which converts an input signal into an output signal of a different form. Examples include the microphone, phonographic pickup, loudspeaker, barometer, photoelectric cell, automobile horn, doorbell, and underwater sound transducer. (McGraw Hill Dictionary of Scientific and Technical Terms, 4th ed) Transducer

Related Publications

S D Cha, and C F Roman, and V Maranhao
August 1987, Anaesthesia and intensive care,
S D Cha, and C F Roman, and V Maranhao
July 1971, Biomedical engineering,
S D Cha, and C F Roman, and V Maranhao
January 1966, Investigative radiology,
S D Cha, and C F Roman, and V Maranhao
October 1981, Neurosurgery,
S D Cha, and C F Roman, and V Maranhao
January 1982, Journal of clinical engineering,
S D Cha, and C F Roman, and V Maranhao
December 2000, Optometry and vision science : official publication of the American Academy of Optometry,
S D Cha, and C F Roman, and V Maranhao
June 1972, The American journal of cardiology,
S D Cha, and C F Roman, and V Maranhao
May 1974, Medical & biological engineering,
S D Cha, and C F Roman, and V Maranhao
February 1972, Iyo denshi to seitai kogaku. Japanese journal of medical electronics and biological engineering,
S D Cha, and C F Roman, and V Maranhao
May 1986, American journal of clinical pathology,
Copied contents to your clipboard!