Physical characteristics and clinical evaluation of a new disposable fibreoptic transducer-tipped catheter system. 1987

E S Barin, and M Cejnar, and G I Nelson, and S N Hunyor
Cardiovascular Research Unit, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.

A new disposable fibreoptic transducer-tipped catheter manometer system was evaluated to assess its accuracy, stability of accuracy under prolonged simulated intra-arterial conditions, and dynamic characteristics. Maximum errors observed in the measurement of static pressure using a sample of five catheters (with one display unit) were 2 mmHg at 0 mmHg reference pressure, 2 at 20 mmHg, 4 at 40 mmHg, 4 at 100 mmHg and 9 at 200 mmHg. An immersion artifact caused a shift in baseline of up to 2 mmHg. Exposure of the transducer to 24 hours of simulated intra-arterial conditions (pulsatile pressure at 40 degrees C) resulted in errors of up to 7 mmHg for pressures up to 100 mmHg, and 11 mmHg for 200 mmHg, which were largely attributable to a drift in baseline pressure (up 6 mmHg by 24 hours). Consistent overestimation by the system suggested inappropriate gain setting within the display unit which, however, is not user-adjustable. The system exhibited uniform frequency response up to 33 Hz.

UI MeSH Term Description Entries
D008365 Manometry Measurement of the pressure or tension of liquids or gases with a manometer. Tonometry,Manometries
D002404 Catheterization Use or insertion of a tubular device into a duct, blood vessel, hollow organ, or body cavity for injecting or withdrawing fluids for diagnostic or therapeutic purposes. It differs from INTUBATION in that the tube here is used to restore or maintain patency in obstructions. Cannulation,Cannulations,Catheterizations
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D005336 Fiber Optic Technology The technology of transmitting light over long distances through strands of glass or other transparent material. Fiber Optic Technologies,Optic Technologies, Fiber,Optic Technology, Fiber,Technologies, Fiber Optic,Technology, Fiber Optic
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000792 Angiography Radiography of blood vessels after injection of a contrast medium. Arteriography,Angiogram,Angiograms,Angiographies,Arteriographies
D014160 Transducers, Pressure Transducers that are activated by pressure changes, e.g., blood pressure. Pressure Transducer,Pressure Transducers,Transducer, Pressure

Related Publications

E S Barin, and M Cejnar, and G I Nelson, and S N Hunyor
January 1989, Indian heart journal,
E S Barin, and M Cejnar, and G I Nelson, and S N Hunyor
June 1972, The American journal of cardiology,
E S Barin, and M Cejnar, and G I Nelson, and S N Hunyor
January 1992, European journal of applied physiology and occupational physiology,
E S Barin, and M Cejnar, and G I Nelson, and S N Hunyor
February 1999, The Journal of bone and joint surgery. American volume,
E S Barin, and M Cejnar, and G I Nelson, and S N Hunyor
January 1988, Catheterization and cardiovascular diagnosis,
E S Barin, and M Cejnar, and G I Nelson, and S N Hunyor
May 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society,
E S Barin, and M Cejnar, and G I Nelson, and S N Hunyor
January 1982, Journal of clinical engineering,
E S Barin, and M Cejnar, and G I Nelson, and S N Hunyor
March 1970, Lancet (London, England),
E S Barin, and M Cejnar, and G I Nelson, and S N Hunyor
April 1987, Lancet (London, England),
Copied contents to your clipboard!