A liquid chromatographic method for the individual determination of benzoic and cinnamic acids in 2 benzoin preparations is presented. The method specifies a reverse phase column and 0.01M KH2PO4-methanol (85 + 15) as mobile phase at a flow rate of 1.8 mL/min, with detection at 254 nm. The method has been applied to 2 benzoin preparations and the results were compared with those from the British Pharmacopoeia method.