Comparison of Intraocular Lens Power Prediction Accuracy Between 2 Swept-Source Optical Coherence Tomography Biometry Devices. 2024

Nir Sorkin, and Rotem Zadok, and Giacomo Savini, and Yoav Kan-Tor, and Yuval Benjamini, and Eliya Levinger, and Judith Bardugo, and Adi Abulafia
Department of Ophthalmology, Tel Aviv Medical Center, Tel Aviv, Israel; Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel. Electronic address: nir.sorkin@gmail.com.

OBJECTIVE To compare intraocular lens (IOL) power prediction accuracy of the Eyestar 900 (EyeS900) and the IOLMaster 700 (IOLM700) based on estimated and measured posterior corneal power. METHODS Retrospective, interinstrument reliability study. METHODS Setting: Institutional. METHODS Two hundred twenty-five eyes of 225 cataract surgery patients. METHODS Patients underwent measurements by both devices preoperatively. METHODS Spherical Equivalent Prediction Error (SEQ-PE), spread of the SEQ-PE (precision) and the absolute SEQ-PE (accuracy) of each device using Barrett Universal II (BUII) formula with either estimated posterior keratometry (E-PK) or measured posterior keratometry (M-PK). RESULTS Trimmed mean SEQ-PEs of EyeS900 E-PK, EyeS900 M-PK, IOLM700 E-PK, and IOLM700 M-PK were 0.03, 0.08, 0.02, and 0.09 D, respectively with no significant differences between EyeS900 E-PK and IOLM700 E-PK (P = 0.31) as well as between EyeS900 M-PK and IOLM700 M-PK (P = 0.31). Statistically significant SEQ-PE differences were found when E-PK and M-PK were compared, regardless of the device used, showing hyperopic SEQ-PE in M-PK calculations. Excellent correlation and agreement in SEQ-PE were found between the devices for both E-PK (P < 0.001, r = 0.848, mean bias: +0.01 D, 95% LOA of -0.32 to +0.34 D) and M-PK (P < 0.001, r = 0.776, mean bias: -0.01 D, 95% LOA of -0.42 to +0.39 D). No significant differences were found comparing absolute SEQ-PE and precision of the devices. CONCLUSIONS The Eyestar 900 and the IOLMaster 700 show comparable IOL power prediction accuracy by the BUII formula using either estimated or measured posterior keratometry. An adjusted lens factor may be required for BUII when utilizing measured posterior keratometry in both devices.

UI MeSH Term Description Entries

Related Publications

Nir Sorkin, and Rotem Zadok, and Giacomo Savini, and Yoav Kan-Tor, and Yuval Benjamini, and Eliya Levinger, and Judith Bardugo, and Adi Abulafia
January 2021, Journal of cataract and refractive surgery,
Nir Sorkin, and Rotem Zadok, and Giacomo Savini, and Yoav Kan-Tor, and Yuval Benjamini, and Eliya Levinger, and Judith Bardugo, and Adi Abulafia
July 2021, [Zhonghua yan ke za zhi] Chinese journal of ophthalmology,
Nir Sorkin, and Rotem Zadok, and Giacomo Savini, and Yoav Kan-Tor, and Yuval Benjamini, and Eliya Levinger, and Judith Bardugo, and Adi Abulafia
January 2019, BMC ophthalmology,
Nir Sorkin, and Rotem Zadok, and Giacomo Savini, and Yoav Kan-Tor, and Yuval Benjamini, and Eliya Levinger, and Judith Bardugo, and Adi Abulafia
January 2023, Clinical ophthalmology (Auckland, N.Z.),
Nir Sorkin, and Rotem Zadok, and Giacomo Savini, and Yoav Kan-Tor, and Yuval Benjamini, and Eliya Levinger, and Judith Bardugo, and Adi Abulafia
January 2022, Clinical ophthalmology (Auckland, N.Z.),
Nir Sorkin, and Rotem Zadok, and Giacomo Savini, and Yoav Kan-Tor, and Yuval Benjamini, and Eliya Levinger, and Judith Bardugo, and Adi Abulafia
September 2018, Scientific reports,
Nir Sorkin, and Rotem Zadok, and Giacomo Savini, and Yoav Kan-Tor, and Yuval Benjamini, and Eliya Levinger, and Judith Bardugo, and Adi Abulafia
June 2017, Journal of cataract and refractive surgery,
Nir Sorkin, and Rotem Zadok, and Giacomo Savini, and Yoav Kan-Tor, and Yuval Benjamini, and Eliya Levinger, and Judith Bardugo, and Adi Abulafia
February 2010, Journal of cataract and refractive surgery,
Nir Sorkin, and Rotem Zadok, and Giacomo Savini, and Yoav Kan-Tor, and Yuval Benjamini, and Eliya Levinger, and Judith Bardugo, and Adi Abulafia
January 2020, Journal of cataract and refractive surgery,
Nir Sorkin, and Rotem Zadok, and Giacomo Savini, and Yoav Kan-Tor, and Yuval Benjamini, and Eliya Levinger, and Judith Bardugo, and Adi Abulafia
December 2021, Expert review of medical devices,
Copied contents to your clipboard!