Calibration of a thermoluminescent dosimetry system to measure effective dose equivalent for 6- to 7-MeV gamma rays. 1986

M L Walsh, and R A Facey

Uncertainty exists as to expected responses of personnel dosimeters when worn in fields of 16N gamma's. Doses to internal organs are also not well known. Accordingly, the response of the Ontario Hydro (OH) TLD badge in terms of the effective dose equivalent (EDE) concept of ICRP Publication 26 was evaluated. Photons at 6-7 MeV were generated from accelerator protons using the 19F (p, alpha gamma)16O* reaction, which closely simulates a 16N-decay gamma field. A phantom containing more than 300 internal TLDs and wearing the OH TLD badges was exposed in stationary and rotational configurations. Ratios of organ dose equivalents (gonads, mean bone marrow, lung and thyroid) to chest badge exposures were 0.6-0.7 for the stationary (frontal) field and 0.7-0.9 for the rotational field. Ratios of EDE to chest badge were 0.60 and 0.77, respectively. The OH TLD badge (and other badges of the same design) will perform satisfactorily in a 16N gamma field under the EDE concept.

UI MeSH Term Description Entries
D008163 Luminescent Measurements Techniques used for determining the values of photometric parameters of light resulting from LUMINESCENCE. Bioluminescence Measurements,Bioluminescent Assays,Bioluminescent Measurements,Chemiluminescence Measurements,Chemiluminescent Assays,Chemiluminescent Measurements,Chemoluminescence Measurements,Luminescence Measurements,Luminescent Assays,Luminescent Techniques,Phosphorescence Measurements,Phosphorescent Assays,Phosphorescent Measurements,Assay, Bioluminescent,Assay, Chemiluminescent,Assay, Luminescent,Assay, Phosphorescent,Assays, Bioluminescent,Assays, Chemiluminescent,Assays, Luminescent,Assays, Phosphorescent,Bioluminescence Measurement,Bioluminescent Assay,Bioluminescent Measurement,Chemiluminescence Measurement,Chemiluminescent Assay,Chemiluminescent Measurement,Chemoluminescence Measurement,Luminescence Measurement,Luminescent Assay,Luminescent Measurement,Luminescent Technique,Measurement, Bioluminescence,Measurement, Bioluminescent,Measurement, Chemiluminescence,Measurement, Chemiluminescent,Measurement, Chemoluminescence,Measurement, Luminescence,Measurement, Luminescent,Measurement, Phosphorescence,Measurement, Phosphorescent,Measurements, Bioluminescence,Measurements, Bioluminescent,Measurements, Chemiluminescence,Measurements, Chemiluminescent,Measurements, Chemoluminescence,Measurements, Luminescence,Measurements, Luminescent,Measurements, Phosphorescence,Measurements, Phosphorescent,Phosphorescence Measurement,Phosphorescent Assay,Phosphorescent Measurement,Technique, Luminescent,Techniques, Luminescent
D008297 Male Males
D008961 Models, Structural A representation, generally small in scale, to show the structure, construction, or appearance of something. (From Random House Unabridged Dictionary, 2d ed) Model, Structural,Structural Model,Structural Models
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011834 Radiation Monitoring The observation, either continuously or at intervals, of the levels of radiation in a given area, generally for the purpose of assuring that they have not exceeded prescribed amounts or, in case of radiation already present in the area, assuring that the levels have returned to those meeting acceptable safety standards. Monitoring, Radiation
D011839 Radiation, Ionizing ELECTROMAGNETIC RADIATION or particle radiation (high energy ELEMENTARY PARTICLES) capable of directly or indirectly producing IONS in its passage through matter. The wavelengths of ionizing electromagnetic radiation are equal to or smaller than those of short (far) ultraviolet radiation and include gamma and X-rays. Ionizing Radiation,Ionizing Radiations,Radiations, Ionizing
D005720 Gamma Rays Penetrating, high-energy electromagnetic radiation emitted from atomic nuclei during NUCLEAR DECAY. The range of wavelengths of emitted radiation is between 0.1 - 100 pm which overlaps the shorter, more energetic hard X-RAYS wavelengths. The distinction between gamma rays and X-rays is based on their radiation source. Gamma Wave,Gamma Radiation,Nuclear X-Rays,Radiation, Gamma,X-Rays, Nuclear,Gamma Radiations,Gamma Ray,Gamma Waves,Nuclear X Rays,Nuclear X-Ray,Ray, Gamma,Wave, Gamma,Waves, Gamma,X Rays, Nuclear,X-Ray, Nuclear
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

M L Walsh, and R A Facey
February 1970, The International journal of applied radiation and isotopes,
M L Walsh, and R A Facey
August 2020, Zeitschrift fur medizinische Physik,
M L Walsh, and R A Facey
January 2006, Radiation protection dosimetry,
M L Walsh, and R A Facey
July 1983, Health physics,
M L Walsh, and R A Facey
January 1971, Radiobiologia, radiotherapia,
M L Walsh, and R A Facey
April 1969, Physics in medicine and biology,
M L Walsh, and R A Facey
January 1970, The American journal of roentgenology, radium therapy, and nuclear medicine,
Copied contents to your clipboard!