A nearly mono-energetic 6-7 MeV photon calibration source. 1983

D W Rogers

A photon source has been developed which delivers about 85% of its photon dose equivalent from photons with energies of 6.1,6.9 and 7.1 MeV produced in the 19F(p, alpha gamma)16O reaction. The source uses up to 50 muA of 2.7 MeV protons incident on a 6 mg/cm2 target of CaF2. It produces a photon field with a dose equivalent rate of up to 6 mSv/h (600 mrem/h) over a large area 100 cm from the target. The field can be calibrated in terms of photon fluence to within +/- 5%. In common with other high-energy photon sources, there is considerable contamination of the field by knock-on electrons and scattered photons. Experiments with various filter materials and detailed Monte-Carlo calculations with the EGS electron-photon transport code have been done to investigate the importance of these contaminants.

UI MeSH Term Description Entries
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D004601 Elementary Particles Individual components of atoms, usually subatomic; subnuclear particles are usually detected only when the atomic nucleus decays and then only transiently, as most of them are unstable, often yielding pure energy without substance, i.e., radiation. Baryons,Fundamental Particles,Baryon,Elementary Particle,Fundamental Particle,Particle, Elementary,Particle, Fundamental,Particles, Elementary,Particles, Fundamental
D005720 Gamma Rays Penetrating, high-energy electromagnetic radiation emitted from atomic nuclei during NUCLEAR DECAY. The range of wavelengths of emitted radiation is between 0.1 - 100 pm which overlaps the shorter, more energetic hard X-RAYS wavelengths. The distinction between gamma rays and X-rays is based on their radiation source. Gamma Wave,Gamma Radiation,Nuclear X-Rays,Radiation, Gamma,X-Rays, Nuclear,Gamma Radiations,Gamma Ray,Gamma Waves,Nuclear X Rays,Nuclear X-Ray,Ray, Gamma,Wave, Gamma,Waves, Gamma,X Rays, Nuclear,X-Ray, Nuclear

Related Publications

D W Rogers
November 2017, The Review of scientific instruments,
D W Rogers
November 1971, Health physics,
D W Rogers
September 1981, International journal of radiation biology and related studies in physics, chemistry, and medicine,
D W Rogers
January 2023, Journal of medical signals and sensors,
D W Rogers
October 1946, The Review of scientific instruments,
Copied contents to your clipboard!