A clinical comparison of Tc-99m HEDP and Tc-99m MDP in the detection of bone metastases: concise communication. 1979

I Fogelman, and D L Citrin, and J H McKillop, and J G Turner, and R G Bessent, and W R Greig

We have compared bone scintigrams made with Tc-99m-tagged HEDP (1-hydroxyethylidene diphosphonate)and MDP (methylene diphosphonate), the former at 4 hr after injection, the latter at both 2 and 4 hr. In 17 patients with skeletal metastases, there was no significant difference in lesion count or scan quality between the 4-hr images. The tumor-to-bone ratio (T/B) was significantly higher with Tc-HEDP (p less than 0.02). Lesion detection rate and T/B ratios were both lower with Tc-MDP at 2 hr when compared with the 4-hr values for both Tc-HEDP (p less than 0.02, p less than 0.005) and Tc-MDP (p less than 0.02, p less than 0.01). The 4-hr Tc-MDP scan was of significantly higher quality than the 2 hr Tc-MDP scan (p less than 0.01). Although Tc-HEDP produces a higher T/B ratio at 4 hr, the present study does not suggest that either agent is superior in clinical practice.

UI MeSH Term Description Entries
D008297 Male Males
D008722 Methods A series of steps taken in order to conduct research. Techniques,Methodological Studies,Methodological Study,Procedures,Studies, Methodological,Study, Methodological,Method,Procedure,Technique
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D009362 Neoplasm Metastasis The transfer of a neoplasm from one organ or part of the body to another remote from the primary site. Metastase,Metastasis,Metastases, Neoplasm,Metastasis, Neoplasm,Neoplasm Metastases,Metastases
D011877 Radionuclide Imaging The production of an image obtained by cameras that detect the radioactive emissions of an injected radionuclide as it has distributed differentially throughout tissues in the body. The image obtained from a moving detector is called a scan, while the image obtained from a stationary camera device is called a scintiphotograph. Gamma Camera Imaging,Radioisotope Scanning,Scanning, Radioisotope,Scintigraphy,Scintiphotography,Imaging, Gamma Camera,Imaging, Radionuclide
D001859 Bone Neoplasms Tumors or cancer located in bone tissue or specific BONES. Bone Cancer,Cancer of Bone,Cancer of the Bone,Neoplasms, Bone,Bone Neoplasm,Neoplasm, Bone
D004164 Diphosphonates Organic compounds which contain P-C-P bonds, where P stands for phosphonates or phosphonic acids. These compounds affect calcium metabolism. They inhibit ectopic calcification and slow down bone resorption and bone turnover. Technetium complexes of diphosphonates have been used successfully as bone scanning agents. Bisphosphonate,Bisphosphonates
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

I Fogelman, and D L Citrin, and J H McKillop, and J G Turner, and R G Bessent, and W R Greig
August 1979, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
I Fogelman, and D L Citrin, and J H McKillop, and J G Turner, and R G Bessent, and W R Greig
March 1982, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
I Fogelman, and D L Citrin, and J H McKillop, and J G Turner, and R G Bessent, and W R Greig
February 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
I Fogelman, and D L Citrin, and J H McKillop, and J G Turner, and R G Bessent, and W R Greig
April 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
I Fogelman, and D L Citrin, and J H McKillop, and J G Turner, and R G Bessent, and W R Greig
November 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
I Fogelman, and D L Citrin, and J H McKillop, and J G Turner, and R G Bessent, and W R Greig
June 1981, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
I Fogelman, and D L Citrin, and J H McKillop, and J G Turner, and R G Bessent, and W R Greig
June 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
I Fogelman, and D L Citrin, and J H McKillop, and J G Turner, and R G Bessent, and W R Greig
March 1991, Clinical nuclear medicine,
I Fogelman, and D L Citrin, and J H McKillop, and J G Turner, and R G Bessent, and W R Greig
August 1977, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
I Fogelman, and D L Citrin, and J H McKillop, and J G Turner, and R G Bessent, and W R Greig
December 1980, Clinical nuclear medicine,
Copied contents to your clipboard!