Transcutaneous PO2 monitoring during pediatric surgery. 1981

B Venus, and K C Patel, and K S Pratap, and H Konchigeri, and D Vidyasagar

The value of continuous transcutaneous oxygen (PtcO2) monitoring in the presence of halothane and nitrous oxide (N2O) was studied in 10 infants. All infants were continuously monitored during the study with a Clark-type skin electrode with Mylar membrane. The polarization voltage of the membrane was changed to 600 mV to make it insensitive to N2O and halothane. The accuracy of PtcO2 electrode was compared with simultaneously measured PaO2 at different intervals. Correlation of PaO2 with PtcO2 was sought during hypoxic-normoxic state (PaO2 between 27--92 torr) and hyperoxic state (PaO2 between 105--439 torr). During hypoxic-normoxic state, the correlation between PaO2 and PtcO2 values was 0.94. During the hyperoxic state, poor correlation existed between PaO2 and PtcO2 (r = 0.51). Although PtcO2 did not correlate with PaO2 during hyperoxia, it consistently overestimated PaO2 and thereby, provided a predictive ability by over-diagnosing hyperoxia. When combined with continuous monitoring of inspired oxygen tension to maintain normoxia, continuous monitoring of PtcO2 will reduce the frequency of PaO2 analysis and improve patient care during anesthesia.

UI MeSH Term Description Entries
D007223 Infant A child between 1 and 23 months of age. Infants
D007231 Infant, Newborn An infant during the first 28 days after birth. Neonate,Newborns,Infants, Newborn,Neonates,Newborn,Newborn Infant,Newborn Infants
D007432 Intraoperative Period The period during a surgical operation. Intraoperative Periods,Period, Intraoperative,Periods, Intraoperative
D008297 Male Males
D008567 Membranes, Artificial Artificially produced membranes, such as semipermeable membranes used in artificial kidney dialysis (RENAL DIALYSIS), monomolecular and bimolecular membranes used as models to simulate biological CELL MEMBRANES. These membranes are also used in the process of GUIDED TISSUE REGENERATION. Artificial Membranes,Artificial Membrane,Membrane, Artificial
D008722 Methods A series of steps taken in order to conduct research. Techniques,Methodological Studies,Methodological Study,Procedures,Studies, Methodological,Study, Methodological,Method,Procedure,Technique
D009609 Nitrous Oxide Nitrogen oxide (N2O). A colorless, odorless gas that is used as an anesthetic and analgesic. High concentrations cause a narcotic effect and may replace oxygen, causing death by asphyxia. It is also used as a food aerosol in the preparation of whipping cream. Laughing Gas,Nitrogen Protoxide,Gas, Laughing,Oxide, Nitrous
D010100 Oxygen An element with atomic symbol O, atomic number 8, and atomic weight [15.99903; 15.99977]. It is the most abundant element on earth and essential for respiration. Dioxygen,Oxygen-16,Oxygen 16
D010313 Partial Pressure The pressure that would be exerted by one component of a mixture of gases if it were present alone in a container. (From McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Partial Pressures,Pressure, Partial,Pressures, Partial
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness

Related Publications

B Venus, and K C Patel, and K S Pratap, and H Konchigeri, and D Vidyasagar
January 1979, Birth defects original article series,
B Venus, and K C Patel, and K S Pratap, and H Konchigeri, and D Vidyasagar
May 1980, Intensive care medicine,
B Venus, and K C Patel, and K S Pratap, and H Konchigeri, and D Vidyasagar
December 1979, Critical care medicine,
B Venus, and K C Patel, and K S Pratap, and H Konchigeri, and D Vidyasagar
January 1985, International journal of clinical monitoring and computing,
B Venus, and K C Patel, and K S Pratap, and H Konchigeri, and D Vidyasagar
February 1985, Critical care medicine,
B Venus, and K C Patel, and K S Pratap, and H Konchigeri, and D Vidyasagar
January 1979, Birth defects original article series,
B Venus, and K C Patel, and K S Pratap, and H Konchigeri, and D Vidyasagar
June 1991, Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae,
B Venus, and K C Patel, and K S Pratap, and H Konchigeri, and D Vidyasagar
February 1978, Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen,
B Venus, and K C Patel, and K S Pratap, and H Konchigeri, and D Vidyasagar
December 1985, Agressologie: revue internationale de physio-biologie et de pharmacologie appliquees aux effets de l'agression,
B Venus, and K C Patel, and K S Pratap, and H Konchigeri, and D Vidyasagar
February 1980, Pediatrics,
Copied contents to your clipboard!