Determinant factors of efficiency of a motor-driven ventricular assist device. 1994

T Nakamura, and K Hayashi, and K Hirano, and T Matsumoto
Department of Electrical and Information Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Japan.

Limiting factors of the system efficiency of an electric-motor-driven ventricular assist device (VAD) consisting of a brushless dc motor and a ball screw in the actuator were analyzed from the balance of force and torque in the pump and actuator. The results suggested that several mechanical components in the actuator should be improved to increase the efficiency. According to the suggestion, rotor material was changed from stainless steel to a lighter engineering plastics; smaller ball bearings were used to reduce rotor inertia; the ball screw was changed from rolled- to ground-execution type; the friction loss in the anti-rotation column inside the ball screw shaft was reduced by changing sliding mechanism to rolling one. These improvements elevated the total system efficiency from 11% to 15%. The new system cleared durability testing of longer than 900 h. More elaborate assembly of the mechanical components of the actuator would increase the efficiency.

UI MeSH Term Description Entries
D008422 Materials Testing The testing of materials and devices, especially those used for PROSTHESES AND IMPLANTS; SUTURES; TISSUE ADHESIVES; etc., for hardness, strength, durability, safety, efficacy, and biocompatibility. Biocompatibility Testing,Biocompatible Materials Testing,Hemocompatibility Testing,Testing, Biocompatible Materials,Testing, Hemocompatible Materials,Hemocompatibility Testings,Hemocompatible Materials Testing,Materials Testing, Biocompatible,Materials Testing, Hemocompatible,Testing, Biocompatibility,Testing, Hemocompatibility,Testing, Materials,Testings, Biocompatibility
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D006353 Heart-Assist Devices Small pumps, often implantable, designed for temporarily assisting the heart, usually the LEFT VENTRICLE, to pump blood. They consist of a pumping chamber and a power source, which may be partially or totally external to the body and activated by electromagnetic motors. Artificial Ventricle,Heart Assist Device,Heart Ventricle, Artificial,Pumps, Heart-Assist,Vascular-Assist Device,Vascular-Assist Devices,Ventricle-Assist Device,Ventricular Assist Device,Artificial Heart Ventricle,Artificial Heart Ventricles,Artificial Ventricles,Assist Device, Heart,Assist Device, Ventricular,Assist Devices, Heart,Assist Devices, Ventricular,Device, Heart Assist,Device, Heart-Assist,Device, Vascular-Assist,Device, Ventricle-Assist,Device, Ventricular Assist,Devices, Heart Assist,Devices, Heart-Assist,Devices, Vascular-Assist,Devices, Ventricle-Assist,Devices, Ventricular Assist,Heart Assist Devices,Heart Ventricles, Artificial,Heart-Assist Device,Heart-Assist Pump,Heart-Assist Pumps,Pump, Heart-Assist,Pumps, Heart Assist,Vascular Assist Device,Vascular Assist Devices,Ventricle Assist Device,Ventricle, Artificial,Ventricle, Artificial Heart,Ventricle-Assist Devices,Ventricles, Artificial,Ventricles, Artificial Heart,Ventricular Assist Devices
D006439 Hemodynamics The movement and the forces involved in the movement of the blood through the CARDIOVASCULAR SYSTEM. Hemodynamic
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D013314 Stress, Mechanical A purely physical condition which exists within any material because of strain or deformation by external forces or by non-uniform thermal expansion; expressed quantitatively in units of force per unit area. Mechanical Stress,Mechanical Stresses,Stresses, Mechanical
D013597 Systems Analysis The analysis of an activity, procedure, method, technique, or business to determine what must be accomplished and how the necessary operations may best be accomplished. Agent-Based Modeling,Analysis, Systems,Complexity Analysis,System Dynamics Analysis,Systems Approach,Systems Medicine,Systems Oriented Approach,Systems Thinking,Agent Based Modeling,Agent-Based Modelings,Analyses, Complexity,Analyses, System Dynamics,Analyses, Systems,Analysis, Complexity,Analysis, System Dynamics,Approach, Systems,Approach, Systems Oriented,Approachs, Systems,Approachs, Systems Oriented,Complexity Analyses,Dynamics Analyses, System,Dynamics Analysis, System,Medicine, Systems,Medicines, Systems,Modeling, Agent-Based,Modelings, Agent-Based,System Dynamics Analyses,Systems Analyses,Systems Approachs,Systems Medicines,Systems Oriented Approachs,Systems Thinkings,Thinking, Systems,Thinkings, Systems

Related Publications

T Nakamura, and K Hayashi, and K Hirano, and T Matsumoto
August 1982, Journal of biomechanical engineering,
T Nakamura, and K Hayashi, and K Hirano, and T Matsumoto
March 1999, Artificial organs,
T Nakamura, and K Hayashi, and K Hirano, and T Matsumoto
January 1986, ASAIO transactions,
T Nakamura, and K Hayashi, and K Hirano, and T Matsumoto
February 1996, Artificial organs,
T Nakamura, and K Hayashi, and K Hirano, and T Matsumoto
October 2013, Artificial organs,
T Nakamura, and K Hayashi, and K Hirano, and T Matsumoto
November 1994, Journal of biomechanics,
T Nakamura, and K Hayashi, and K Hirano, and T Matsumoto
January 1989, ASAIO transactions,
T Nakamura, and K Hayashi, and K Hirano, and T Matsumoto
June 1999, Artificial organs,
T Nakamura, and K Hayashi, and K Hirano, and T Matsumoto
September 2011, Nihon rinsho. Japanese journal of clinical medicine,
T Nakamura, and K Hayashi, and K Hirano, and T Matsumoto
January 2017, Kyobu geka. The Japanese journal of thoracic surgery,
Copied contents to your clipboard!