Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. 1995

C Prussin, and D D Metcalfe
Allergic Diseases Section, National Institute of Allergy and Infectious Diseases, Bethesda, MD 20892-1888, USA.

Recently, there have been several reports demonstrating improvements in the flow cytometric detection of intracellular cytokines. These advances, although significant, have not yielded techniques that have easily been translated into broad use. To address this issue, we have coupled a fixation and permeabilization method with the use of directly labelled monoclonal anti-cytokine antibodies, providing both improved signal and simpler staining. The kinetics of in situ cytokine production in both CD4 and CD8 cells are shown for IL-2, IL-4, IL-5 and IFN-gamma. Based on these data, 6 h was chosen for optimal detection of this combination of cytokines. We show the specificity of this technique by blocking cytokine staining using a molar excess of recombinant cytokine. Additionally, unlabelled anti-cytokine antibodies are demonstrated to block specific staining of labelled antibody, providing an objective means to place statistical markers. Using such controls, we routinely detected as few as 0.1% false positive cells, allowing the flow cytometric detection of IL-5, which is below the threshold of detection of published methods. To further prove the specificity of staining, we stained using two anti-IL-5 mAbs known to recognize different epitopes and demonstrate that the same cells stain with both antibodies. Without permeabilization we could detect a fraction of cells with low intensity staining for cytokine. This staining was further examined using differential two color staining for intracellular and extracellular cytokine, clearly demonstrating no cells staining exclusively for extracellular cytokine, confirming a lack of passive transfer of cytokine to nearby cells. We show that cytokine flow cytometry is useful in examining the increased IL-5 production characteristic of eosinophilic states and that IL-5 production is limited to the CD27 negative subpopulation. These data illustrate the unique capability of cytokine flow cytometry to correlate cytokine expression with cell surface phenotype without cell separation. In summary, using directly conjugated anti-cytokine antibodies, cytokine flow cytometry becomes a specific and versatile technique for the assessment of complex cytokine production phenotypes in fresh ex vivo T cell subpopulations.

UI MeSH Term Description Entries
D007700 Kinetics The rate dynamics in chemical or physical systems.
D008565 Membrane Proteins Proteins which are found in membranes including cellular and intracellular membranes. They consist of two types, peripheral and integral proteins. They include most membrane-associated enzymes, antigenic proteins, transport proteins, and drug, hormone, and lectin receptors. Cell Membrane Protein,Cell Membrane Proteins,Cell Surface Protein,Cell Surface Proteins,Integral Membrane Proteins,Membrane-Associated Protein,Surface Protein,Surface Proteins,Integral Membrane Protein,Membrane Protein,Membrane-Associated Proteins,Membrane Associated Protein,Membrane Associated Proteins,Membrane Protein, Cell,Membrane Protein, Integral,Membrane Proteins, Integral,Protein, Cell Membrane,Protein, Cell Surface,Protein, Integral Membrane,Protein, Membrane,Protein, Membrane-Associated,Protein, Surface,Proteins, Cell Membrane,Proteins, Cell Surface,Proteins, Integral Membrane,Proteins, Membrane,Proteins, Membrane-Associated,Proteins, Surface,Surface Protein, Cell
D011994 Recombinant Proteins Proteins prepared by recombinant DNA technology. Biosynthetic Protein,Biosynthetic Proteins,DNA Recombinant Proteins,Recombinant Protein,Proteins, Biosynthetic,Proteins, Recombinant DNA,DNA Proteins, Recombinant,Protein, Biosynthetic,Protein, Recombinant,Proteins, DNA Recombinant,Proteins, Recombinant,Recombinant DNA Proteins,Recombinant Proteins, DNA
D003593 Cytoplasm The part of a cell that contains the CYTOSOL and small structures excluding the CELL NUCLEUS; MITOCHONDRIA; and large VACUOLES. (Glick, Glossary of Biochemistry and Molecular Biology, 1990) Protoplasm,Cytoplasms,Protoplasms
D004802 Eosinophilia Abnormal increase of EOSINOPHILS in the blood, tissues or organs. Eosinophilia, Tropical,Hypereosinophilia,Tropical Eosinophilia,Hypereosinophilias,Tropical Eosinophilias
D005434 Flow Cytometry Technique using an instrument system for making, processing, and displaying one or more measurements on individual cells obtained from a cell suspension. Cells are usually stained with one or more fluorescent dyes specific to cell components of interest, e.g., DNA, and fluorescence of each cell is measured as it rapidly transverses the excitation beam (laser or mercury arc lamp). Fluorescence provides a quantitative measure of various biochemical and biophysical properties of the cell, as well as a basis for cell sorting. Other measurable optical parameters include light absorption and light scattering, the latter being applicable to the measurement of cell size, shape, density, granularity, and stain uptake. Cytofluorometry, Flow,Cytometry, Flow,Flow Microfluorimetry,Fluorescence-Activated Cell Sorting,Microfluorometry, Flow,Cell Sorting, Fluorescence-Activated,Cell Sortings, Fluorescence-Activated,Cytofluorometries, Flow,Cytometries, Flow,Flow Cytofluorometries,Flow Cytofluorometry,Flow Cytometries,Flow Microfluorometries,Flow Microfluorometry,Fluorescence Activated Cell Sorting,Fluorescence-Activated Cell Sortings,Microfluorimetry, Flow,Microfluorometries, Flow,Sorting, Fluorescence-Activated Cell,Sortings, Fluorescence-Activated Cell
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000906 Antibodies Immunoglobulin molecules having a specific amino acid sequence by virtue of which they interact only with the ANTIGEN (or a very similar shape) that induced their synthesis in cells of the lymphoid series (especially PLASMA CELLS).
D000911 Antibodies, Monoclonal Antibodies produced by a single clone of cells. Monoclonal Antibodies,Monoclonal Antibody,Antibody, Monoclonal
D000918 Antibody Specificity The property of antibodies which enables them to react with some ANTIGENIC DETERMINANTS and not with others. Specificity is dependent on chemical composition, physical forces, and molecular structure at the binding site. Antibody Specificities,Specificities, Antibody,Specificity, Antibody

Related Publications

C Prussin, and D D Metcalfe
March 1994, Rinsho byori. The Japanese journal of clinical pathology,
C Prussin, and D D Metcalfe
January 2000, Memorias do Instituto Oswaldo Cruz,
C Prussin, and D D Metcalfe
May 1984, Journal of immunological methods,
C Prussin, and D D Metcalfe
January 2019, Frontiers in immunology,
C Prussin, and D D Metcalfe
September 1993, Rinsho byori. The Japanese journal of clinical pathology,
C Prussin, and D D Metcalfe
January 2014, Methods in molecular biology (Clifton, N.J.),
C Prussin, and D D Metcalfe
January 1996, Clinical and experimental immunology,
C Prussin, and D D Metcalfe
April 2002, Journal of neuroimmunology,
Copied contents to your clipboard!