We present a case of open-chest cardiac massage where ventricular fibrillation developed and a direct current shock was required. In the absence of 'surgical' electrode paddles, standard paddle electrodes were used; one small electrode was placed directly on the exposed epicardial surface and the second electrode was placed on the lateral chest wall. Defibrillation was achieved with a 100 J shock. This combined epicardial-transthoracic electrode paddle placement technique allows defibrillation to be accomplished when open chest cardiac massage is being performed and no 'surgical' electrode paddles are available.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010496 Pericardium A conical fibro-serous sac surrounding the HEART and the roots of the great vessels (AORTA; VENAE CAVAE; PULMONARY ARTERY). Pericardium consists of two sacs: the outer fibrous pericardium and the inner serous pericardium. The latter consists of an outer parietal layer facing the fibrous pericardium, and an inner visceral layer (epicardium) resting next to the heart, and a pericardial cavity between these two layers. Epicardium,Fibrous Pericardium,Parietal Pericardium,Pericardial Cavity,Pericardial Space,Serous Pericardium,Visceral Pericardium,Cavities, Pericardial,Cavity, Pericardial,Pericardial Cavities,Pericardial Spaces,Pericardium, Fibrous,Pericardium, Parietal,Pericardium, Serous,Pericardium, Visceral,Pericardiums, Fibrous,Pericardiums, Serous,Serous Pericardiums,Space, Pericardial,Spaces, Pericardial
D011183 Postoperative Complications Pathologic processes that affect patients after a surgical procedure. They may or may not be related to the disease for which the surgery was done, and they may or may not be direct results of the surgery. Complication, Postoperative,Complications, Postoperative,Postoperative Complication
D012086 Reoperation A repeat operation for the same condition in the same patient due to disease progression or recurrence, or as followup to failed previous surgery. Revision, Joint,Revision, Surgical,Surgery, Repeat,Surgical Revision,Repeat Surgery,Revision Surgery,Joint Revision,Revision Surgeries,Surgery, Revision
D012151 Resuscitation The restoration to life or consciousness of one apparently dead. (Dorland, 27th ed) Resuscitations
D004554 Electric Countershock An electrical current applied to the HEART to terminate a CARDIAC ARRHYTHMIA. Cardiac Electroversion,Cardioversion,Defibrillation, Electric,Electroversion, Cardiac,Electrical Cardioversion,Electroversion Therapy,Therapy, Electroversion,Cardiac Electroversions,Cardioversion, Electrical,Cardioversions,Cardioversions, Electrical,Countershock, Electric,Countershocks, Electric,Defibrillations, Electric,Electric Countershocks,Electric Defibrillation,Electric Defibrillations,Electrical Cardioversions,Electroversion Therapies,Electroversions, Cardiac,Therapies, Electroversion
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D006336 Heart Massage Rhythmic compression of the heart by pressure applied manually over the sternum (closed heart massage) or directly to the heart through an opening in the chest wall (open heart massage). It is done to reinstate and maintain circulation. (Dorland, 28th ed) Cardiac Massage,Cardiac Massages,Heart Massages,Massage, Cardiac,Massage, Heart,Massages, Cardiac,Massages, Heart

Related Publications

R E Kerber, and J E Davis
May 1992, The Annals of thoracic surgery,
R E Kerber, and J E Davis
June 1995, IEEE transactions on bio-medical engineering,
R E Kerber, and J E Davis
January 1977, Heart & lung : the journal of critical care,
R E Kerber, and J E Davis
July 1989, Medical & biological engineering & computing,
R E Kerber, and J E Davis
September 1980, The American journal of cardiology,
R E Kerber, and J E Davis
March 2003, Pacing and clinical electrophysiology : PACE,
R E Kerber, and J E Davis
February 1996, Journal of the American College of Cardiology,
R E Kerber, and J E Davis
June 1959, American journal of surgery,
Copied contents to your clipboard!