Transthoracic defibrillation: importance of avoiding electrode placement directly on the female breast. 1996

L A Pagan-Carlo, and K T Spencer, and C E Robertson, and A Dengler, and C Birkett, and R E Kerber
Department of Internal Medicine, University of Iowa Hospital, Iowa City 52242, USA.

OBJECTIVE This study sought to determine the effect on transthoracic impedance of placement of defibrillation electrodes on the female breast versus adjacent to or under the breast. BACKGROUND Transthoracic impedance is a major determinant of transthoracic current flow in defibrillation. For a given energy setting, a high transthoracic impedance reduces current flow and may adversely affect the ability of electric shocks to accomplish defibrillation. We hypothesized that the increased interelectrode tissue associated with placement of the apex defibrillation electrode on the female breast would result in increased transthoracic impedance compared with electrode placement lateral to or under the breast. METHODS Transthoracic impedance was measured noninvasively by passing a 5-V, 31.25-kHz square wave current through the chest and comparing the low level current flow to known references. We measured transthoracic impedance associated with three different apex defibrillation electrode positions--on the breast, under the breast and lateral to the breast--in 25 women (brassiere size 34A to 48C, 25 to 75 years old, body weight 128 to 328 lb [58 to 148 kg] and 2 men. The measurements were taken with a modified defibrillator that accurately predicts transthoracic impedance without delivering an actual shock. The measurement sequence was random. RESULTS The average measured transthoracic impedance with placement of the apex defibrillation electrode on the breast was 95 +/- 25 ohms (mean +/- SD), under the breast 84 +/- 17* ohms and lateral to the breast 83 +/- 20* ohms (asterisk indicates p < 0.01 vs. on the breast by analysis of variance). The study cohort was also classified into two groups: large breasted (brassiere size > or = 40) and small breasted (brassiere size < or = 39). The measured transthoracic impedances for the large-breasted group were 112 +/- 20 ohms for on the breast, 94 +/- 13* ohms for under the breast and 98 +/- 19* ohms for lateral to the breast. For the small breasted group, the similar transthoracic impedance measurements were 81 +/- 21, 77 +/- 16 and 71 +/- 13* ohms, respectively. CONCLUSIONS In women, placement of the apex defibrillation electrode on the breast results in higher transthoracic impedance, which will reduce current flow. We recommend placing the apex electrode lateral to or underneath the breast.

UI MeSH Term Description Entries
D008297 Male Males
D008408 Mastectomy Surgical procedure to remove one or both breasts. Mammectomy,Mammectomies,Mastectomies
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D001940 Breast In humans, one of the paired regions in the anterior portion of the THORAX. The breasts consist of the MAMMARY GLANDS, the SKIN, the MUSCLES, the ADIPOSE TISSUE, and the CONNECTIVE TISSUES. Breasts
D004554 Electric Countershock An electrical current applied to the HEART to terminate a CARDIAC ARRHYTHMIA. Cardiac Electroversion,Cardioversion,Defibrillation, Electric,Electroversion, Cardiac,Electrical Cardioversion,Electroversion Therapy,Therapy, Electroversion,Cardiac Electroversions,Cardioversion, Electrical,Cardioversions,Cardioversions, Electrical,Countershock, Electric,Countershocks, Electric,Defibrillations, Electric,Electric Countershocks,Electric Defibrillation,Electric Defibrillations,Electrical Cardioversions,Electroversion Therapies,Electroversions, Cardiac,Therapies, Electroversion
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly

Related Publications

L A Pagan-Carlo, and K T Spencer, and C E Robertson, and A Dengler, and C Birkett, and R E Kerber
June 1998, Resuscitation,
L A Pagan-Carlo, and K T Spencer, and C E Robertson, and A Dengler, and C Birkett, and R E Kerber
June 1997, Resuscitation,
L A Pagan-Carlo, and K T Spencer, and C E Robertson, and A Dengler, and C Birkett, and R E Kerber
July 1999, The American journal of cardiology,
L A Pagan-Carlo, and K T Spencer, and C E Robertson, and A Dengler, and C Birkett, and R E Kerber
January 2008, IEEE transactions on information technology in biomedicine : a publication of the IEEE Engineering in Medicine and Biology Society,
L A Pagan-Carlo, and K T Spencer, and C E Robertson, and A Dengler, and C Birkett, and R E Kerber
March 2005, Medical & biological engineering & computing,
L A Pagan-Carlo, and K T Spencer, and C E Robertson, and A Dengler, and C Birkett, and R E Kerber
October 1989, The American journal of cardiology,
L A Pagan-Carlo, and K T Spencer, and C E Robertson, and A Dengler, and C Birkett, and R E Kerber
December 1988, Pediatrics,
L A Pagan-Carlo, and K T Spencer, and C E Robertson, and A Dengler, and C Birkett, and R E Kerber
January 2016, Prehospital emergency care,
L A Pagan-Carlo, and K T Spencer, and C E Robertson, and A Dengler, and C Birkett, and R E Kerber
May 1997, Annals of emergency medicine,
L A Pagan-Carlo, and K T Spencer, and C E Robertson, and A Dengler, and C Birkett, and R E Kerber
September 2000, The American journal of cardiology,
Copied contents to your clipboard!