Endocardial electrograms and pacemaker sensing. 1976

P Hurzeler, and V De Caprio, and S Furman

Endocardial electrograms in 77 acute cases (at time of pacemaker implant) and 56 chronic cases (at time of pulse generator replacement, with electrodes in service for at least 6 months) were recorded. The peak-to-peak voltage and rate of rise, or slew rate, were compared acutely and chronically. Both parameters must simultaneously exceed given thresholds to trigger the sensing circuits of implantable pacemakers. The average chronic slew rate was half the average acute value. The maximum slew rate and voltage swing occur during the intrinsic deflection as a virtually straight line segment of the electrogram. The findings are consistent with the predictions of a mathematical model for genesis of the electrogram, and also with a model for explaining acute-to-chronic changes in stimulation current thresholds.

UI MeSH Term Description Entries
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

P Hurzeler, and V De Caprio, and S Furman
July 1968, Circulation,
P Hurzeler, and V De Caprio, and S Furman
July 1979, Kokyu to junkan. Respiration & circulation,
P Hurzeler, and V De Caprio, and S Furman
February 1977, The Journal of thoracic and cardiovascular surgery,
P Hurzeler, and V De Caprio, and S Furman
November 1977, Circulation,
P Hurzeler, and V De Caprio, and S Furman
July 1980, Pacing and clinical electrophysiology : PACE,
P Hurzeler, and V De Caprio, and S Furman
November 1979, The Journal of the Florida Medical Association,
P Hurzeler, and V De Caprio, and S Furman
November 1986, Pacing and clinical electrophysiology : PACE,
P Hurzeler, and V De Caprio, and S Furman
May 1968, The Journal of thoracic and cardiovascular surgery,
P Hurzeler, and V De Caprio, and S Furman
May 1967, The Journal of thoracic and cardiovascular surgery,
P Hurzeler, and V De Caprio, and S Furman
January 1967, Israel journal of medical sciences,
Copied contents to your clipboard!