Presynaptic modulation of Lymnaea neurons evoked by computer-generated spike trains. 1998

A Szucs, and K S Rózsa, and J Salánki
Balaton Limnological Research Institute of the Hungarian Academy of Sciences, Tihany.

To investigate the functional organisation and information processing in Lymnaea neuronal networks, artificial spike trains were elicited in one of the main respiratory interneurons (RPeD1) and the modulation of the firing patterns of postsynaptic cells was examined. This was performed by precisely timing the action potential generation of the presynaptic cell using a computer-controlled voltage clamp amplifier (pattern clamp technique). Induced oscillation (0.1-0.4 Hz) in the firing pattern of RPeD1 spread to a large number of postsynaptic cells, as clearly demonstrated by Fourier power spectra. At the same time, no signs of precise (millisecond) spike timing was observed in the cells studied. The results confirm that the neurons used in our experiments process information as pure rate-coders.

UI MeSH Term Description Entries
D008195 Lymnaea A genus of dextrally coiled freshwater snails that includes some species of importance as intermediate hosts of parasitic flukes. Lymnea,Lymnaeas,Lymneas
D008564 Membrane Potentials The voltage differences across a membrane. For cellular membranes they are computed by subtracting the voltage measured outside the membrane from the voltage measured inside the membrane. They result from differences of inside versus outside concentration of potassium, sodium, chloride, and other ions across cells' or ORGANELLES membranes. For excitable cells, the resting membrane potentials range between -30 and -100 millivolts. Physical, chemical, or electrical stimuli can make a membrane potential more negative (hyperpolarization), or less negative (depolarization). Resting Potentials,Transmembrane Potentials,Delta Psi,Resting Membrane Potential,Transmembrane Electrical Potential Difference,Transmembrane Potential Difference,Difference, Transmembrane Potential,Differences, Transmembrane Potential,Membrane Potential,Membrane Potential, Resting,Membrane Potentials, Resting,Potential Difference, Transmembrane,Potential Differences, Transmembrane,Potential, Membrane,Potential, Resting,Potential, Transmembrane,Potentials, Membrane,Potentials, Resting,Potentials, Transmembrane,Resting Membrane Potentials,Resting Potential,Transmembrane Potential,Transmembrane Potential Differences
D008838 Microcomputers Small computers using LSI (large-scale integration) microprocessor chips as the CPU (central processing unit) and semiconductor memories for compact, inexpensive storage of program instructions and data. They are smaller and less expensive than minicomputers and are usually built into a dedicated system where they are optimized for a particular application. "Microprocessor" may refer to just the CPU or the entire microcomputer. Computers, Personal,Microprocessors,Computer, Personal,Microcomputer,Microprocessor,Personal Computer,Personal Computers
D009474 Neurons The basic cellular units of nervous tissue. Each neuron consists of a body, an axon, and dendrites. Their purpose is to receive, conduct, and transmit impulses in the NERVOUS SYSTEM. Nerve Cells,Cell, Nerve,Cells, Nerve,Nerve Cell,Neuron
D004558 Electric Stimulation Use of electric potential or currents to elicit biological responses. Stimulation, Electric,Electrical Stimulation,Electric Stimulations,Electrical Stimulations,Stimulation, Electrical,Stimulations, Electric,Stimulations, Electrical
D004594 Electrophysiology The study of the generation and behavior of electrical charges in living organisms particularly the nervous system and the effects of electricity on living organisms.
D000200 Action Potentials Abrupt changes in the membrane potential that sweep along the CELL MEMBRANE of excitable cells in response to excitation stimuli. Spike Potentials,Nerve Impulses,Action Potential,Impulse, Nerve,Impulses, Nerve,Nerve Impulse,Potential, Action,Potential, Spike,Potentials, Action,Potentials, Spike,Spike Potential
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D017729 Presynaptic Terminals The distal terminations of axons which are specialized for the release of neurotransmitters. Also included are varicosities along the course of axons which have similar specializations and also release transmitters. Presynaptic terminals in both the central and peripheral nervous systems are included. Axon Terminals,Nerve Endings, Presynaptic,Synaptic Boutons,Synaptic Terminals,Axon Terminal,Bouton, Synaptic,Boutons, Synaptic,Ending, Presynaptic Nerve,Endings, Presynaptic Nerve,Nerve Ending, Presynaptic,Presynaptic Nerve Ending,Presynaptic Nerve Endings,Presynaptic Terminal,Synaptic Bouton,Synaptic Terminal,Terminal, Axon,Terminal, Presynaptic,Terminal, Synaptic,Terminals, Axon,Terminals, Presynaptic,Terminals, Synaptic
D018408 Patch-Clamp Techniques An electrophysiologic technique for studying cells, cell membranes, and occasionally isolated organelles. All patch-clamp methods rely on a very high-resistance seal between a micropipette and a membrane; the seal is usually attained by gentle suction. The four most common variants include on-cell patch, inside-out patch, outside-out patch, and whole-cell clamp. Patch-clamp methods are commonly used to voltage clamp, that is control the voltage across the membrane and measure current flow, but current-clamp methods, in which the current is controlled and the voltage is measured, are also used. Patch Clamp Technique,Patch-Clamp Technic,Patch-Clamp Technique,Voltage-Clamp Technic,Voltage-Clamp Technique,Voltage-Clamp Techniques,Whole-Cell Recording,Patch-Clamp Technics,Voltage-Clamp Technics,Clamp Technique, Patch,Clamp Techniques, Patch,Patch Clamp Technic,Patch Clamp Technics,Patch Clamp Techniques,Recording, Whole-Cell,Recordings, Whole-Cell,Technic, Patch-Clamp,Technic, Voltage-Clamp,Technics, Patch-Clamp,Technics, Voltage-Clamp,Technique, Patch Clamp,Technique, Patch-Clamp,Technique, Voltage-Clamp,Techniques, Patch Clamp,Techniques, Patch-Clamp,Techniques, Voltage-Clamp,Voltage Clamp Technic,Voltage Clamp Technics,Voltage Clamp Technique,Voltage Clamp Techniques,Whole Cell Recording,Whole-Cell Recordings

Related Publications

A Szucs, and K S Rózsa, and J Salánki
June 1974, Iyo denshi to seitai kogaku. Japanese journal of medical electronics and biological engineering,
A Szucs, and K S Rózsa, and J Salánki
February 1975, The Journal of physiology,
A Szucs, and K S Rózsa, and J Salánki
January 2000, Acta biologica Hungarica,
A Szucs, and K S Rózsa, and J Salánki
January 1975, Brain research,
A Szucs, and K S Rózsa, and J Salánki
October 2017, PLoS computational biology,
A Szucs, and K S Rózsa, and J Salánki
January 1982, Neuroscience and biobehavioral reviews,
A Szucs, and K S Rózsa, and J Salánki
September 2015, Biochimica et biophysica acta,
A Szucs, and K S Rózsa, and J Salánki
August 2010, Brain research,
Copied contents to your clipboard!