Pain-evoked blink reflex. 1997

J Ellrich, and B Bromm, and H C Hopf
Institute of Physiology, University Hospital Eppendorf, Hamburg, Germany.

The electrically evoked blink reflex (BR) consists of an ipsilateral R1 component (R1) at 11 ms and two bilateral components R2 at 33 ms and R3 at 83 ms. It is still unclear whether the R2 is mediated by activation of tactile or nociceptive afferents. For testing the nociceptive hypothesis, nociceptors of the supraorbital nerve were selectively activated by infrared laser stimuli in 10 subjects. Only painful laser stimuli evoked a bilateral early polyphasic BR response (LR2) at 71 ms. Stimulation of infraorbital and mental nerve dermatomes was equally effective. A late bilateral reflex response at 130 ms was occasionally observed. Regarding the nociceptor activation time of about 40 ms, onset latencies were within the range of the electrically evoked R2 and R3, respectively. The good accordance of R2 and LR2 may be due to activation of identical nociceptive fibers or to convergence of electrically evoked tactile and laser-elicited nociceptive input onto common multireceptive neurons.

UI MeSH Term Description Entries
D007259 Infrared Rays That portion of the electromagnetic spectrum usually sensed as heat. Infrared wavelengths are longer than those of visible light, extending into the microwave frequencies. They are used therapeutically as heat, and also to warm food in restaurants. Heat Waves,Heat Wave,Infrared Ray,Ray, Infrared,Rays, Infrared,Wave, Heat,Waves, Heat
D007834 Lasers An optical source that emits photons in a coherent beam. Light Amplification by Stimulated Emission of Radiation (LASER) is brought about using devices that transform light of varying frequencies into a single intense, nearly nondivergent beam of monochromatic radiation. Lasers operate in the infrared, visible, ultraviolet, or X-ray regions of the spectrum. Masers,Continuous Wave Lasers,Pulsed Lasers,Q-Switched Lasers,Continuous Wave Laser,Laser,Laser, Continuous Wave,Laser, Pulsed,Laser, Q-Switched,Lasers, Continuous Wave,Lasers, Pulsed,Lasers, Q-Switched,Maser,Pulsed Laser,Q Switched Lasers,Q-Switched Laser
D008046 Lip Either of the two fleshy, full-blooded margins of the mouth. Philtrum,Lips,Philtrums
D008297 Male Males
D009424 Nervous System Physiological Phenomena Characteristic properties and processes of the NERVOUS SYSTEM as a whole or with reference to the peripheral or the CENTRAL NERVOUS SYSTEM. Nervous System Physiologic Processes,Nervous System Physiological Processes,Nervous System Physiology,Nervous System Physiological Concepts,Nervous System Physiological Phenomenon,Nervous System Physiological Process,Physiology, Nervous System,System Physiology, Nervous
D009619 Nociceptors Peripheral AFFERENT NEURONS which are sensitive to injuries or pain, usually caused by extreme thermal exposures, mechanical forces, or other noxious stimuli. Their cell bodies reside in the DORSAL ROOT GANGLIA. Their peripheral terminals (NERVE ENDINGS) innervate target tissues and transduce noxious stimuli via axons to the CENTRAL NERVOUS SYSTEM. Pain Receptors,Receptors, Pain,Nociceptive Neurons,Neuron, Nociceptive,Neurons, Nociceptive,Nociceptive Neuron,Nociceptor,Pain Receptor
D009915 Orbit Bony cavity that holds the eyeball and its associated tissues and appendages. Eye Socket,Eye Sockets,Orbits,Socket, Eye,Sockets, Eye
D010146 Pain An unpleasant sensation induced by noxious stimuli which are detected by NERVE ENDINGS of NOCICEPTIVE NEURONS. Suffering, Physical,Ache,Pain, Burning,Pain, Crushing,Pain, Migratory,Pain, Radiating,Pain, Splitting,Aches,Burning Pain,Burning Pains,Crushing Pain,Crushing Pains,Migratory Pain,Migratory Pains,Pains, Burning,Pains, Crushing,Pains, Migratory,Pains, Radiating,Pains, Splitting,Physical Suffering,Physical Sufferings,Radiating Pain,Radiating Pains,Splitting Pain,Splitting Pains,Sufferings, Physical
D011930 Reaction Time The time from the onset of a stimulus until a response is observed. Response Latency,Response Speed,Response Time,Latency, Response,Reaction Times,Response Latencies,Response Times,Speed, Response,Speeds, Response
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference

Related Publications

J Ellrich, and B Bromm, and H C Hopf
August 2011, Cephalalgia : an international journal of headache,
J Ellrich, and B Bromm, and H C Hopf
October 1987, Journal of neurology,
J Ellrich, and B Bromm, and H C Hopf
January 1995, Experimental brain research,
J Ellrich, and B Bromm, and H C Hopf
February 2015, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society,
J Ellrich, and B Bromm, and H C Hopf
February 1981, Neurology,
J Ellrich, and B Bromm, and H C Hopf
October 1983, Harefuah,
J Ellrich, and B Bromm, and H C Hopf
October 1984, Neurology,
J Ellrich, and B Bromm, and H C Hopf
June 1994, Electroencephalography and clinical neurophysiology,
J Ellrich, and B Bromm, and H C Hopf
February 1989, Journal of mental deficiency research,
J Ellrich, and B Bromm, and H C Hopf
January 1991, Japanese journal of ophthalmology,
Copied contents to your clipboard!